Although the target temperature has
been reached, the heating system
does not run
This may be related to the
Stop and
Run Interval Settings
of Cosa.
In your application, there are two
values under
Heating and Cooling
Settings
as “
Stop” and “Run”
intervals
. For example, if the stopping
range is 0.3
℃
, the operating range is
0.1
℃
, and the target temperature of
your home is set as 22
℃
, Cosa will
stop your heating system at 22.3
℃
,
and start it at 21.9
℃
. Therefore, by
changing these intervals according
to your preferences
, you can make
your heating system work shorter and
more frequently or longer and less
frequently.