Fault finding
Note:
The alarms and the warnings of the system are presented in previous chapter, including
instructions on how to address them. Many of them require the dehumidifier manual.
Symptom
Probable cause
Measure
The Control Panel
does not work.
The display does not
show anything
If batteries are used, these might be
empty.
The power adaptor is not connected
or broken.
Replace batteries.
Verify that the power adaptor is
connected to the power outlet
and that there is power in the
outlet (connect another consumer
to the outlet such as a lamp or a
radio)
Verify that the power connector
cable is correctly positioned in the
Control Panel.
If the problem remains, insert
batteries (1.5V AAA cells) in the
Control Panel. If this works, the
power adaptor is broken and
needs to be replaced.
If none of the above works, the
Control Panel itself is probably
out of order. Please contact your
retailer.
The Control Panel
does not log anything-
The USB stick can be malfunctioning
or, if used anywhere else before,
incorrectly formated.
Verify that the USB stick, if it has
been used anywhere else, is FAT
32 formated.
If this does not work, replace the
USB stick with another FAT32
formated stick.
If the problem remains, please
contact your retailer.