CORRADI SPA
- USER MANUAL - PALLADIA
46 of 121
20.05.2013
ADJUSTING THE COMMANDS
ELECTRIC DRIVE TYPE 1 (PLAN 75 MOTOR)
B
A
M1
1
2
3
1
3
2
A
B
PLAN 75 Motor
230 V/50 Hz
In= 0,97 A
Pn= 218 W
IP= 54
Open male plug
supplied
Insulated extend
button 230 V
WIRE TYPE
FG70R 3X1,5 mmq
WIRE TYPE
FG70R 3X1,5 mmq
W
ORK MUST BE C
ARRIED OUT B
Y INST
ALLER
COMMON
EX
TEND
RE
TR
A
CT
Insulated retract
button 230 V
RESER
VED
FOR
QU
ALIFIED
TECHNICIANS
RESER
VED
FOR
QU
ALIFIED
TECHNICIANS
LIMIT STOP ADJUSTMENT PLAN 75 MOTOR
The end user of the product must refer to the limit stop adjustment
procedure described here below. This procedure differs from the initial
adjustment of the motor set by the technical installer (see Installation
Manual).
LIMIT SWITCH: OPENING (AWNING EXTENDED)
If the INSTALLATION KIT panel is present, connect it to the motor so that it
can be manoeuvred.
N.B. For those who don’t have a push-button panel ask a qualified
technician to realize one, as in the wiring scheme.
Run down the awning to the pre-set position for the opening limit switch;
the awning must be in this position to set the opening limit switch.
Push the
A*
button on the motor box using a screwdriver, making a slight
rotation, block the push-button in depressed position. The actual limit
switch will be cancelled.
When the push-button is pushed inside, operate the panel until the
awning is in the right limit switch position. Press pushbutton
A
with a
screwdriver and turn slightly to release, to
store the limit switch position and quit the procedure.
*Do not try to force the push-button if it does not move when pressed,
but ensure that the motor is positioned on the limit switch.
LIMIT SWITCH: CLOSING (AWNING RETRACTED)
Connect the panel to the motor. Raise the awning to the preset position
for the closing limit switch. The awning must be in this position to set
the closing limit switch. Press push-button
B*
on the motor body with a
screwdriver, turning it slightly in order to secure the push-button.
When the push-button is pushed inside and secured, operate the panel
until the awning is in the right limit switch position.
Press push-button
B
with a screwdriver and turn slightly to release, to store
the limit switch position and quit the procedure.