Residual risks
2.3
Risk
Preventive measure
Re. in the
manual
Risk of crushing during the cans
loading and unloading operations.
Wear appropriate personal protective equipment
(shoes and gloves).
Risk of crushing during the auto
-
matic movement of the humidifier
cap.
The machine must be used by a single operator.
Keep hands away from the dispensing area at all
times while the machine is operating.
Risk of crushing during the move
-
ment of the shelf.
Wear appropriate personal protective equipment
(shoes and gloves).
Risk of electrocution if you per
-
form any operation without first
cutting off electrical power.
The operator is not authorized to access the machine
parts protected by panels.
Before removing the panels, unplug the power supply
cable from the mains socket outlet.
Risk of electrocution caused by
high leakage current.
Power the machine through a grounded socket outlet.
Dorsal/lumbar injuries caused by
handling of heavy loads.
Do not exceed the weight limits stated by the
current regulations in force (kg 20 for women, kg
30 for men).
Contact or inhalation of colo-
rants during the canister refilling
operations.
Keep the room suitably ventilated.
Wear appropriate personal protective equipment
(safety goggles, gloves and mask).
Contact or inhalation of colorants
during the cleaning operations of
the nozzle center and moistening
of the humidifier cap sponge.
Exposure to laser beam.
The Bung Hole Locator (B.H.L.) uses red laser light
sources which can be potentially dangerous for the
eyes.
AVOID STARING AT THE LIGHT SOURCE.
Fire due to the use of colorants
containing volatile solvents.
Do not use naked flames, electrical tools or other
types of devices that could cause sparks or fire
hazards close to the machine.
The room in which the machine is installed must be spa-
cious, with good ventilation (air exchange) and no type
of parts must be leant against or stocked close to the
machine.
Canister top up must be carried out opening one canis-
ter at the time.
If during this operation, some colorant should spill out of
the canister, immediately disconnect the machine from
the mains before cleaning.