ORDINARY MAINTENANCE
- 33
ORIGINAL INSTRUCTIONS
Cleaning and moistening the humidifier cap sponge
7.6
In case of sponge replacement, use only those supplied with the machine.
8 mm
To remove the Autocap screw(s)
Open the Autocap...
1.
I
using the command in the management
software.
II
bringing the machine to the off-line 2 condition,
by means of the off-line button.
Disconnect power supply (
2.
If present, open the inspection door provided in the nozzles area.
3.
Loosen the screw
4.
A
and remove the sponge support
B
by turning it counter-clockwise.
A
B
WITHOUT HUMIDIFIER SYSTEM
WITH WATER HUMIDIFIER SYSTEM
Check the condition of the sponge and moisten
a.
as needed. The level of the humidifying liquid
must not exceed the height of the sponge. If it
is very dirty, remove the sponge from the cap
and wash it thoroughly. Replace it if it is se-
verely damaged.
Check the condition of the sponge. If it is very
b.
dirty, remove the sponge from the cap and wash it
thoroughly.