background image

Standard Recommended Procedure 206-455-AEN | Issue 1 | November 2018 | Page 11 of 14

Step 2: 

Use the supplied brush to apply a third of the UCN lubricant to the sealing ring channel on the end 

cap 

(Figure 24)

.

Step 3: 

Stretch the sealing ring over the channel.

Step 4: 

Fold the edge of the seal that overlaps the outside of the end cap until the seal seats in the channel as 

shown in 

Figure 25

.

Step 5: 

Retain a small amount of UCN lubricant for later use. Apply the remaining lubricant to all sides of the 

sealing ring.

12.2  Install the Canister Cover.

Step 1: 

Slide the canister over the closure assembly.

Step 2: 

Loosen bolt on the hinged side of the clamping ring.

Step 3: 

Apply a thin coat of UCN lubricant retained previously to the threads of the clamping ring latch bolts 

to prevent the bolts from seizing on reentry.

Step 4: 

Place the clamping ring over the flange of the canister and the sealing ring. Ensure that both the 

sealing    ring and the canister flange are within the clamping ring 

(Figure 26)

.

Step 5: 

Swing the clamping ring into closing position. Tighten the bolts until the plastic on the ring touches, 

then tighten a quarter turn until the ring is completely closed.

IMPORTANT: 

A torque value of 25 to 50 in-lb should be sufficient to close the clamping ring. Do not use power 

tools to tighten the ring; a torque value of more than 80 in-lb causes the hardware to crack and 

the clamping ring to become defective. If the clamping ring does not close properly, make sure the 

sealing ring and clamping ring are oriented correctly.

LU

BR

IC

AN

T

TPA-5997

Figure 24 

UCN LUBRICANT

KPA-1719

Figure 25 

Summary of Contents for SCF-1296

Page 1: ...ed Procedures Figure 1 TPA 6313 Table of Contents 1 General 2 2 Tools and Materials 2 3 Carton Contents 2 4 Prepare the Cable 2 5 Prepare End Cap 4 6 Continue Cable Preparation 4 7 Install Strain reli...

Page 2: ...heat shink tube branching clip and UCN lubricant 4 Prepare the Cable CAUTION The wearing of cut resistant safety gloves to protect your hands from accidental injury when using sharp bladed tools and...

Page 3: ...o cable manufacturer s instructions Figure 2 IMPORTANT Do not expose the bare fibers until after the cable has been placed in the closure end cap Do not untwist the subunits or remove their jacketing...

Page 4: ...n 7 mm 28 in min N A 41 4 mm 1 65 in max 28 mm 1 10 in max 32 5 mm 1 29 in max 15 5 mm 60 in max 12 7 mm 58 in max N A Figure 5 a Carefully tap the end using a punch or a nut driver Figure 6 b Clean t...

Page 5: ...a immediately with soap and water to avoid irritation Do not induce vomiting if paste or cleaner is ingested IMPORTANT Torches are not recommended for the application of the heat shrink tubes included...

Page 6: ...le 9 Attach Frame to End Cap Step 1 Remove splice plane and slack storage covers Section Figure 12 Figure 12 Step 2 Secure the end cap on the work surface table with the express cable to the top Step...

Page 7: ...pment P N RST 000 or equivalent and separate ribbon matrix within 6 in of cable sheath opening Secure this separation point with tape Step 1 Form the subunits from each cable into a single slack loop...

Page 8: ...er s tape NOTE Only use the ribbon splitting tool on the first two to four inches of ribbon Clean excess ribbon matrix from the tool often Split the rest of the ribbon length by hand Step 5 Create a l...

Page 9: ...d splice a To ensure the appropriate length of slack fibers cut the fibers extending beyond the bottom of the closure as shown in Figure 20 b Remove the tape from the fibers c Remove the fibers from t...

Page 10: ...ices Install the second splice on top of the first splice before proceeding to the next slot in the organizer Step 5 Secure the spliced ribbons in the clips on the splicing plane Confirm the fibers do...

Page 11: ...etained previously to the threads of the clamping ring latch bolts to prevent the bolts from seizing on reentry Step 4 Place the clamping ring over the flange of the canister and the sealing ring Ensu...

Page 12: ...sure with no leaks Step 3 After the flash test has been performed and the closure sealed correctly carefully remove the air valve and allow air to escape 14 Ground the Closure Optional Step 1 Apply a...

Page 13: ...h member is metal bend it over the slots in the extension bracket as shown in the inset in Figure 30 and then trim excess strength member Step 5 Wrap the strength member yarn around the restraint cap...

Page 14: ...Optical Communications is available at www corning com opcomm trademarks All other trademarks are the properties of their respective owners Corning Optical Communications is ISO 9001 certified 2018 C...