4.7.2.2
CLASS1 Connector (Local Plant Feed)
Note: In order to power the MRU via the CLASS1 connector (2 pole terminal plug), the DC bridge must be moved from the
default CLASS2 mode position to CLASS1.
DC CLASS1 power specs:
•
Power input: 48 VDC (40-60VDC)
•
Max. current consumption: 9 A
To perform CLASS1 DC connector wiring
1. Loosen PEM captive screws and pull out module from chassis. See Figure
4-22.
Figure
4-22. Extracting PEM from Chassis
2. Move DC bridge from CLASS2 position to CLASS1 to set DC input source type to ‘CLASS1’ connector. Refer to
Figure
4-23.
Figure
4-23. Setting CLASS1 Mode