I ns t al l at i o n C MA - XX X- A E N
P a ge 2 7
Draft
4.2.3
Outdoor Installation
This section provides instructions on how to install the MRU in a Purcell cabinet (Flexsure® 12-2420) and perform external
alarm connections between the unit and the enclosure.
Note the following:
•
The MRU, outdoor enclosure and required dry contact alarms cable are each ordered separately
•
Additional relevant documentation - Purcell Flexsure 12-2420 installation manual provided with the cabinet
•
Only trained and qualified personnel should be allowed to install, replace, or service this equipment
•
The MRU connections are performed after the chassis is installed in cabinet
4.2.3.1
Items Required for Outdoor Installation
Refer to Table
4-3 for the items required for installing the MRU in the outdoor enclosure.
Kit
Item
Quantity
FLX12-2420 Enclosure Purcell Flexsure® 12RU Outdoor GR-487 Enclosure for
single MRU installations
1
MRU
Mid-Power remote unit
1
External Alarms Cable
(AK-MRU-DCA-CBL)
DB9 male open wire cable for external alarm connections
1
Table
4-3. Items Required for Outdoor Installation
Additional required items (not provided):
•
Standard electrician tools (including ratchet wrench with extension bar and 8 mm socket) for tightening self-drilling
screws securing MRU chassis to cabinet rails)
•
Assorted cable ties
•
90
◦
right angle
4.3-10 type male connector coax cables – one for antenna connection and one for external 2.5 GHz RF
source connection (if relevant)
•
Recommended - Flexible cable conduits for routing connections cables through cabinet knockouts; refer to Figure
4-6
for relevant knockouts; Following are recommended Heyco part numbers for flexible conduits:
Manufacturer PN
Description
8406
HFC 1 BLACKw/8467 Nut, conduit fitting 1 in thread
8453
HF2 1 Tubing 100’ Coil Black
8456
HFC 2 Tubing 50’ Coil Black
8642
HFC 2 Black; conduit fitting 2 in thread
Table
4-4. Recommended Conduits
•
Sealing material for knockouts – if not using conduits