Signature Service Manual
© 2011, IMI Cornelius Inc.
- 39 -
Publication Number: 621058426SER
Figure 55. 120VAC Power Connections
AC Cable Replacement
for 230VAC Units
If a power cord becomes frayed or damaged, it may be replaced by simply pulling it
out of the power entry module connector and replacing it with a new cord, as shown
in Figure 56.
Figure 56. Rear View of Unit Showing 230VAC/50 Hz Connection
3
Disconnect the AC and Ground connections to the E-Box terminals. (See Fig-
ure 55.)
4
Remove the strain relief and route the cable down through the unit.
5
Replace the cable with new wiring. (be sure strain relief is properly seated)
6
Route the new wiring from the bottom of the unit following the old wiring path.
7
Connect the new wiring to the proper terminals in the E-Box.
8
Connect the wiring to the protected circuit or plug the plug into the proper
receptacle. Verify the proper operating voltage before connecting the unit.
Table 26.
Step
Procedure
AC Connections
Ground
Connection
AC Connection