IDC 2XX with Cold Carbonation Installation Manual
© 2005-2019, Cornelius Inc.
- 19 -
Publication Number: 621057403INS
Beverage is too sweet
Valve brix requires adjustment
Adjust valve brix
Carbonator is not operating
Repair carbonator
No CO
2
in carbonator
Restore CO
2
pressure in carbonator
City water pressure supply low or inconsistent
Booster pump must be used if dynamic water
pressure drops below 40 psig.
Unit will not dispense
carbonated drinks. Dis-
penses syrup only.
CO
2
pressure in carbonator tank is too high.
Check CO
2
pressure regulator setting. 75 psig
recommended. Relieve pressure from carbon-
ator tank.
Water valve will not open
Check electrical connection to water valve.
Check resistance of coil (should be 9 ohms).
Check for voltage at coil when brand button is
depressed.
Unit will not dispense
carbonated drinks.
Spurts CO
2
and syrup
only.
Carbonator tank is empty, because tank was
emptied while power was applied to unit. 5
minute time-out of carbonator pump/motor
occurred, and carbonator pump is locked off.
Unplug the unit and reconnect the unit. Main
control board will reset, ice agitation will occur,
and carbonator tank will refill to normal level.
Note that this can occur while the water filter
system is serviced or water supply is shutoff. If
drinks are drawn from the dispenser while
water pressure is shutoff, the carbonator pump
starts and runs continuously, then shuts off on
the 5 minute timeout.
1) low water pressure switch deactivates car-
bonator pump, 2) after 5 minutes reset and
retry carbonator pump. If water supply is
restored, the 5 minute timeout will not occur.
Repeat reset a second time, but on a third
time, then lockout carbonator pump, which will
generate a service call.
Carbonated drinks are
flat (low on carbonation)
CO
2
is out
Replace CO
2
Carbonator tank is 100% filled because the
city water pressure exceeds the carbonator
tank CO
2
pressure regulator setting.
CO
2
setting for the carbonator tank is 75 psig,
max water pressure is 60 psig. If necessary,
install a water pressure regulating valve.
Low water pressure
Could be caused by excessively long runs
(over 40 ft.) of 3/8” water supply line.
Increase line size to 1/2”
Low water pressure
Add water pressure booster pump
Plugged water filter.
Change water filter
Water booster bladder has burst
Replace water booster tank/bladder
No Syrup or Watered
down drink dispensed
Syrup supply is empty
Replace BIB
BIB pump not working
Replace BIB pump
No CO
2
or compressed air supply to BIB
pump, or not enough pressure
Check CO
2
pressure regulator setting. 65 psig
recommended. Replace CO
2
tank or fix com-
pressor.
Carbonator Troubleshooting
Symptom
Cause
Remedy
Carbonator pump does
not start to fill tank
Power cord for the carbonator pump motor is
not connected.
Carbonator pump is powered off the main con-
trol board inside the electrical box of the unit.
Check that the umbilical cord is connected
from the unit to the pump motor terminal box.