Figure 38.
R
EPLACING
THE
S
OLENOID
C
OIL
The solenoid valve, shown in Figure 38, is located at the left rear of the unit, behind
the access panel. To replace the solenoid coil, perform the procedure in Table 25.
Figure 39.
Solenoid
Valve
High
Pressure
Switch
Reset
Button
Table 25.
Step
Action
1
Turn off the electrical supply to the unit.
2
Remove the access panel from the rear of the unit.
3
Remove the electrical connections to the solenoid, shown in Figure 39.
4
Pull the solenoid off of the valve stem.
5
Replace the solenoid by pressing the new solenoid onto the valve stem, as
shown in Figure 40.
6
Reconnect the wiring to the solenoid.
7
Replace the access panel.
8
Turn on the electrical supply to the unit.
Electrical
Connections