There are two carbonators in the Energize6 unit. To replace a carbonator, perform
the procedure in Table 21.
Ice Probe
Assembly
Table 21.
Step
Action
1
Determine which carbonator is malfunctioning.
2
Turn off the electrical supply to the unit.
3
Turn off the water supply to the unit.
4
Turn off the CO
2
supply to the unit.
5
Remove the cover using the procedure in “Removing the Unit Cover” on page 14
6
Drain the bath by removing the overflow tube from the unit.
7
Thaw the ice bank. This can be accelerated by pouring warm water into the
water bath.
8
Drain the system pressure by opening a dispense valve.
9
To gain access to the carbonator tank, remove the agitator bracket from the
unit, as shown in “Replacing the Agitator Motor” on page 26.
10
Carefully slide the bracket out of the way.
11
Open the carbonator relief valves and depressurize the carbonators,
shown in Figure 32.