Technical Support Manual – 05/2015 Rel. 0
Page 11
028
INN IMB
OPERATOR
CONFIRMATION
WARNING: Launch with weight on the
internal side during the Cal3 calibration
phase. In this phase, the weight must be
on the external side.
Remove the weight from the internal side and
repeat the launch. If the error persists, contact
technical support.
030
CAR CAL
OPERATOR
CONFIRMATION
WARNING: Lack of calibration data for
the CAR/SUV Wheel Type.
Carry out calibration for the CAR/SUV Wheel
Type.
036
NO IMB
ONCE
WARNING: Absence of wheel imbalance
in DYNAMIC mode. It is not possible to
run the low speed SWI procedure.
037
NO IMB
ONCE
WARNING: Absence of wheel imbalance
in STATIC mode. It is not possible to run
the low speed SWI procedure.
050
NO HYD
OPERATOR
CONFIRMATION
WARNING: Absence of wheel external
imbalance. It is not possible to use the
Hidden Weight program.
051
TOO FAR
OPERATOR
CONFIRMATION
WARNING: Hidden Weights programme:
the selected point is too far from the
external imbalance position.
The point must be included up to 120° from the
external imbalance position.
052
NOT INC
OPERATOR
CONFIRMATION
WARNING: Hidden Weights programme:
the external imbalance position is not
between the selected W1 and W2
points.
Choose W1 and W2 points so that they include
the external imbalance position.
055
NO OPT
OPERATOR
CONFIRMATION
WARNING: The static imbalance of the
wheel is too low: the Optimisation
programme cannot be used.
061
BAD CMD
ONCE
ERROR: Serial control not
acknowledged.
ONLY TECHNICAL PERSONNEL.
The serial control sent to the machine has not
been acknowledged as valid.
062
BAD TAS
OPERATOR
CONFIRMATION
ERROR: The pressed key is not permitted
or an incorrect password has been
entered.
Press the permitted key or enter the correct
password.
(1)
The error code can be exited in the following ways:
OPERATOR
CONFIRMATION
The machine exits the error code display when the operator presses any key (except for [P7]
).
OPERATOR ACTION
The machine exits from the error code display when the operator performs an action linked to said
error code (for example, ERR 016 brings the Distance sensor back to the rest position).
ONCE
The machines displays once the error code and its brief description, then it returns to the previous
status.
PERMANENT
The machine permanently displays this error code until its turn-off, therefore the error code cannot
be exited.
7. ACOUSTIC SIGNALS
The machine emits different acoustic signals based on its status. The acoustic signals are listed in table T7.1.
Table T7.1: Acoustic signals
Signal
Meaning
Notes
Short beep
Selecting a programme or a function
Double beep
Warning
A particular condition has occurred that requires the
operator's attention.
Triple beep
Function not available or Error
The requested function is not available or that an error
condition has occurred.
Short beep + long beep
Storing one or more values in the permanent
memory (eeprom) of the circuit board
One or more values have been stored in the permanent
memory of the circuit board (for example, at
completion of calibration phases).
Intermittent beep
Adjustment
Signal used in some service programmes to simplify the
adjustment of sensors.
The acoustic signal is also heard for about two seconds at machine start up allowing the operator to check the operation of the alarm
(buzzer).