background image

 

Technical Support Manual – 05/2015 Rel. 0                        

Page 10 

10.

 

Manually rotate the wheel until a value of 50 appears on the right display. Apply the 50 g weight at the 12 o'clock position 
on the external side of the wheel; 

11.

 

Manually run a launch by acting on the locking ring with knobs; 

12.

 

Calibration is complete: the machine automatically exits the calibration program and returns to NORMAL mode, ready to 
perform the balancing. 

If during machine calibration anomalies occur, error codes will be displayed (e.g. 

Err 025

). Refer to chapter 

“6. Error codes”

 and 

act accordingly to resolve the problem and continue/repeat/cancel the calibration in progress. 
 
How to exit the CAR/SUV Wheel Type calibration 

You can exit the ongoing calibration procedure at any time by pressing [F+P3]

. The machine will return to 

SERVICE mode displaying 

SER SER

. To return to NORMAL mode, press [F+P3]

The calibration in progress will be cancelled and the machine will make use of the previous calibration data. 
 

6. ERROR CODES AND WARNINGS 

The machine indicates error conditions by alternating the display of the error code with a brief description (in English) of the cause 
of the error. The machine displays the code for different times depending on the code of said error, as indicated in the "Display" 
column in table T6.1. 

Table T6.1: Error codes 

Codice  

Descrizione 

sintetica 

Visualizzazione

(1)

 

Descrizione 

Note 

000 a 
009 

INT ERR 

 

ERROR: Machine parameters internal 

error. 

Replace CPU board. 

010 

REV SPN 

 

ERROR: Reverse rotation of the wheel. 

Replace power board. 

 

020 

NO EEP 

OPERATOR 

CONFIRMATION 

ERROR: Lack of communication with the 

eeprom memory. 

Turn the machine off and then on again. If the 

error persists, replace the CPU board. 

011 

SPD LOW 

 

WARNING: Wheel speed too low. 

1.

 

Check the mains voltage. 

2.

 

Check the tension of the belt and 

pulley. 

015 

Damaged key 
code 

PERMANENT 

UNTIL TURNED 

OFF 

ERROR: Damaged keys upon activation. 

Release all buttons, then turn off or restart the 

machine. If the error persists, replace the CPU 

board. 

019 

NO CP 

OPERATOR 

CONFIRMATION 

WARNING: Communication  processor 

failure. 

Turn the machine off and then on again. If the 

error persists, contact technical support. 

The machine can still be used but all functions 

related to the USB port are disabled. 

021 

EEP ERR 

OPERATOR 

CONFIRMATION 

WARNING: Lack of machine calibration 

data or incorrect calibration data. 

Carry out calibration for the CAR/SUV Wheel 

Type and/or for the MOTO Wheel Type. If the 

error persists, contact technical support.  

See also ERR 030. 

022 

-A- OUT 

OPERATOR 

CONFIRMATION 

ERROR: Pick-up channel A too high. 

Excessive imbalance or anomaly. Turn the 

machine off and then on again. If the error 

persists, check for pick-up failure Replace pick-

up. 

023 

-B- OUT 

OPERATOR 

CONFIRMATION 

ERROR: Pick-up channel B too high. 

Excessive imbalance or anomaly. Turn  the 

machine off and then on again. If the error 

persists, check for pick-up failure Replace pick-

up. 

024 

TIM OUT 

OPERATOR 

CONFIRMATION 

ERROR: Internal timer channel too high. 

Excessive imbalance or anomaly. Turn the 

machine off and then on again. If the error 

persists, check for pick-up failure Replace pick-

up. 

026 

NO –A- 

OPERATOR 

CONFIRMATION 

WARNING: A launch without weight or 

failure of the pick-up A signal in the Cal2 

calibration phase. 

Apply the intended weight and repeat the launch. 

If the error persists, contact technical support. 

027 

NO –B- 

OPERATOR 

CONFIRMATION 

WARNING: A launch without weight or 

failure of the pick-up B signal in the Cal2 

calibration phase. 

Apply the intended weight and repeat the launch. 

If the error persists, contact technical support. 

Summary of Contents for MEC 1

Page 1: ...EQUILIBRATRICI MEC 1 MEC 1 BAT TECHNICAL SUPPORT MANUAL UK...

Page 2: ......

Page 3: ...ter reset spin 8 4 PICK UP SPRING PRE CHARGE REGULATION 8 5 MACHINE CALIBRATION 9 5 1 When to carry out machine calibration 9 5 2 How to calibrate the machine for CAR SUV wheel type 9 How to exit the...

Page 4: ...with a series of TEST programs that can be used to detect any anomaly The TEST programs are grouped inside the Test Programs menu Figure F2 1 Machine use controls Table T2 1 Settings programs and Men...

Page 5: ...urn to SERVICE mode 4 Press keys F P9 to confirm the option 5 5 To exit the TEST Programs Menu select the Menu option Ret and press keys F P9 ENC ENCODER disc test This menu option allows you to run t...

Page 6: ...est When you access this option the display shows the message SIG SIG as shown in figures F2 6 and F2 7 Figure F2 6 Pick up signal test message Figure F2 7 Pick up signal message To perform this test...

Page 7: ...he VFC TEST described below If only one pick up signal differs considerably from the values indicated in table T9 2 check if I The cables of pick ups A and B have been connected to the wrong connector...

Page 8: ...ter voltage frequency test This menu option allows you to run the converter voltage frequency test or VFC of the CPU C1 board When you access this option the display shows digits AAA BBB as shown in f...

Page 9: ...the password by pressing the keys in the sequence indicated within 5 seconds or the machine will return to SERVICE mode a P2 b P4 c P5 d P9 The password must not be disclosed to the end user as he she...

Page 10: ...erly the pick up must be pre charged with a spring In order to do so the spring must be compressed with a screw according to that described below 1 Manually tighten the hex screw until it stops 2 Repe...

Page 11: ...have relevant and constant room temperature and humidity variations e g seasonal changes Recommended End user and or SERVICE Technical Support A non calibrated machine provides balancing results equa...

Page 12: ...he CPU board 011 SPD LOW WARNING Wheel speed too low 1 Check the mains voltage 2 Check the tension of the belt and pulley 015 Damaged key code PERMANENT UNTIL TURNED OFF ERROR Damaged keys upon activa...

Page 13: ...as not been acknowledged as valid 062 BAD TAS OPERATOR CONFIRMATION ERROR The pressed key is not permitted or an incorrect password has been entered Press the permitted key or enter the correct passwo...

Page 14: ...high The values displayed are too low The value displayed is 0 The value of the signals must range between 70 110 Connection cable not welded on the pick up Connection cable not connected to CPU Pick...

Page 15: ...N OF MACHINE The figures F10 1 e F10 2 show a detailed scheme of the machine Figure F10 1 Electrical wiring of the machine without internal battery MEC 1 It is possible to order the following codes 1...

Page 16: ...t Manual 05 2015 Rel 0 Page 14 Figure F10 2 Electrical wiring of the machine with internal battery MEC 1 BAT It is possible to order the following codes 1 Cod 21201019 Power supply board 2 Cod 2120102...

Page 17: ...anel The CPU C1 board collects the analogue signals of pick ups A and B and the sensor data encoder disc activates the electric motor processes the pick up signals and the sensor data and displays the...

Page 18: ......

Page 19: ...CORMACH S r l via A Pignedoli 2 42015 CORREGGIO RE ITALY Tel 39 0522 631274 Fax 39 0522 631284 e mail cormach cormachsrl com www cormachsrl com...

Reviews: