11
After the above information is confirmed, relevant controller operations can be carried out:
1.Please read the user manual of the controller carefully before operation, and then start
the controller.
2.Set the controller’ output voltage to zero first.
3.Check no abnormal phenomenon, then input voltage value (via keyboard or analog
control) according to specified input voltage range.
4.Operating normally within the rated voltage range of piezoelectric ceramics (0~120V,
maximum 150V).
5.After use, please carry out voltage reset operation.
Please take light steps when XD601-D2 in operation, do not knock the product, so as not
to affect the use of the product or even damage the product.
The resolution of the product itself is unlimited, and the resolution depends on
the performance of the controller. In order to achieve better motion precision, it is
recommended to use our company's supporting controller. Please refer to the user manual
of the controller for the specific operation to ensure correct operation before relevant
operation.
Notes:
Do not remove the grounding protection during the operation. If you need to remove
it temporarily, please reconnect the grounding protection before starting it again.
The driving voltage shall not exceed the voltage range of XD601-D2(150V).
If any abnormal noise or oscillation occurs during use, turn off the power immediately
and check the parameter setting.