LOGGED DATA
When an error occurs, additional system data that represents the state of the system at the instance the
error occurs is recorded as an entry into a list of error log entries visible from the maintenance mode. The
total number of error log entries is 10. The makeup of the logged entry data that is common to all equipment
configurations is defined in the following table:
Description
Meaning/Definition
Error Code
This is the error code mentioned in the Machine Error Codes section.
Operating
Hours
The total number of machine operating hours that have elapsed at the
time the error occurs.
Operating
Distance
The odometer distance of the machine at the time the error occurs in
units that are dependent on the machine type.
Treadmill Common Error Logged Data
In addition to the data listed in the previous Machine Error Common Logged Data section, the treadmill
equipment configuration includes more last error list data:
Description
Meaning/Definition
Belt Target
Speed
The target speed of the belt in 10th’s of a mph or kph (depending on
units).
Instant Belt
Target PWM
The instant target Pulse Width Modulated duty cycle value that is sent
to the motor controller to control the target speed of the belt.
Belt Detected
Speed
The actual speed of the belt in 10th’s of a mph or kph (depending on
units).
Workout
Elapsed Time
Elapsed time in seconds of an ongoing workout at the time of the error.
DFR code
Error Code received from Motor Controller at time of error (if applica-
ble). See separate document for DFR error code listings.
Program ID
Id of program being executed at the time of the error occurrence. The
value matches the ID returned in response to the CSAFE command,
cmdGetProgram.
Total Error
Count
Count of the total number of errors recorded by the system at the time
this error is recorded. Note that the number has been incremented to
include this current error. The number is also limited to a max of 9999.
Beyond 9999, the number rolls over to 0.
Deck Grade
Elevation Grade of the Deck in units of 0.1 percent elevation.
Elevation A/D
Tics
A/D tic representation of the voltage position signal returned from the
elevation motor potentiometer.