17
SE LP10 Integrated Wired
With and Without MELR Option (Electric Latch Retraction)
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights
reserved. Reproduction in whole or in part without the express written permission of ASSA
ABLOY Access and Egress Hardware Group, Inc. is prohibited.
7 Fire Plate Installation and Earth Ground Connection
1. Install two (2) #8 x 1/2” self-drill screws in the bottom-most pair of holes
in the mounting plate (Fig. 7A).
Feed lower left screw through green/yellow ground wire ring terminal.
Ensure that green/yellow wire points toward top of door in order to avoid
interference with escutcheon.
2. Fasten plate with two #8 x 1 1/4” Phillips pan head self-drilling screws.
Note: For non-fire rated doors, omit fire plate.
8A Position Inside Escutcheon & Wires (Non-MELR)
1. Carefully and neatly fold lock body wires onto themselves. ElectroLynx
connectors should be positioned side-by-side under the fire block plate.
Device connectors should be positioned side-by-side on top of the
ElectroLynx connectors.
2. Position inside escutcheon in order to ensure wires are not pinched.
Adjust wires as necessary to ensure they are clear of rear escutcheon.
Seat inside escutcheon against door.
Note: Be sure to cover, but not pinch wires when mounting escutcheon.
3. Insert two (2) #8-32 x 5/8” Phillips flat head escutcheon screws and thread
into mounting plate.
Fig. 8A
(Non-MELR)
(2) #8-32 x 5/8” Phillips
Flat Head Under-cut
Machine Screws
Inside of
Door
7. Install two (2) #8 x 1/2” self-drill screws in the bottom-most pair of holes in
the mounting plate (Fig. 6F).
Inside of
Door
Fig. 7A
(2) 1/4” self-
drilling screws