Z-wave command classes
Command Class
Version
Description
BASIC
V1
• Basic SET: Not Supported
• Basic GET: Multilevel Sensor Get
• Basic REPORT: Multilevel Sensor
Report (1°C accuracy)
MANUFACTURER_
SPECIFIC
V2
Danfoss and qheat RS IDs
VERSION
V2
Version of the command classes,
the Z-wave library and the qheat RS
BATTERY
V1
Battery status
MULTI_CMD
V1
Conserve battery, transmitting multi-
ple commands in a single packet
WAKE_UP
V2
Wake-up interval range 5 min. to
24h (default: 60 minutes)
PROTECTION
V2
0 = No protection
2 = User interface locked
CONFIGURATION
V2
qheat RS specific configuration.
SENSOR_
MULTILEVEL
V6
Reports reading from the room
temperature sensor.
CENTRAL_SCENE
V1
Pushing the LED button triggers
transmission of CENTRAL_SCENE_
NOTIFICATION.
THERMOSTAT_
SETPOINT
V2
When a set-point temperature is
selected on the display, a set-point
report containing the value is sent to
the controller.
SCHEDULE
V1
When a temperature and number of
hours are selected on the display,
an override schedule report will be
sent to the controller containing
the values.
INDICATOR
V1
Control of the LED indication.
GB
qheat
DTHERMZ5 10/2015
7
Installation & User Guide qheat room sensor