65
USER'S MANUAL
1-
Take off the frame the unit cover. Take off the
front frame far maintenance according to the
following steps:
•
Turn perpendicular airflow direction handle from" I
"to horizontal direction.
•
As shown in the picture on the right, take off two
covers from the front frame and then unfasten two
fixture screws.
•
Pull the front frame towards yourself and take it off.
In case that put the front frame back, turn the
perpendicular airflow direction handle from "1 "to
horizontal, then proceed according to
the third and the second steps.
You should check whether the front frame is firmly
inside the fixture groove on the top.
2-
Check the water exhausting.
•
Put a cup of water into groove.
•
Check whether the water flow through the water
exhausting hole.
•
The outdoor unit must be firmly fixed to avoid falling in the strong wind.
•
lnstall on the cement base the drawing below.
•
lf it will be installed at seaside or at a place high above the ground and with strong wind, the
AC should be installed against the wall to en sure the normal operation of the fan and the
blocking plate should be used.
•
lf it will be installed in type, the structure of the mounting surface should be made of solid
stick, cement or materials with equivalent strength, and be of enough bearing capacity.
Otherwise, measures such as reinforcement, support or vibration damping should be adopted.
Check the water exhausting
lnstallation of the outdoor unit
lnstallation outdoor unit bolt
Model
Unit Size
800x315x545
834x328x655
540
335
985x395x808
675
409
1 drive 2
1 drive 3
1 drive 4
1 drive 5
545
315
A(mm) B(mm)