Notices of installation
Requirements For lnstallation Position
•
Avoid places of inflammable or explosive gas leakage or where there are strongly
aggressive gases.
•
Avoid places subject to strong artificial electric/magnetic fields.
•
Avoid places subject to noise and resonance.
•
Avoid severe natural conditions (e.g. heavy lampblack, strong sandy wind, direct
sunshine or high temperature heat sources).
•
Avoid places within the reach of children.
•
Shorten the connection between the indoor and outdoor units.
•
Select where it is easy to perform service and repair and where the ventilation good.
•
The outdoor unit shall not be installed in any way that could occupy an aisle, stairway,
exit, fire escape, catwalk or any other public area.
•
The outdoor unit shall be installed as far as possible from the doors and windows of the
neighbors as well as the green plants.
Installation environment inspection
•
Check nameplate of outdoor unit to make sure whether the refrigerant is R32.
•
Check the floor space of the room. The space shall not be less than usable space{sm2)
in the specification.The outdoor unit shall be installed at a well-ventilated place.
•
Check the surrounding environment of installation site: R32 shall not be installed in the
enclosed reserved space of a building.
•
When using electric drill to make holes in the wall, check first whether there is
pre-buried pipeline far water, electricity and gas. it is suggested to use the reserved hole
in the roof of the wall.