14
3.1 RS485 TERMINATION SETTING
Note
:
It is possible to connect multiple speed dome cameras in parallel provided that No. 10 switch ID code of the
farthest camera is set to “ON”. The switch will apply a 120
Ω
impedance offset resistance. The operation is also required
for a single camera especially when the installation has long cable runs.
The No. 10 ID code should be set to “ON” for the last camera connected to the daisy chain to set at 120
Ω
.
4.PROTOCOL SETTING
Protocol of this speed dome is set through a 3 segment DIL switch.
Below is the detail of setting protocol code:
NOTE:
THE BLACK SEGMENT REPRESENTS THE SWITCH (NOT THE WHITE SEGMENT).
Power off before changing settings -
DO NOT Power on until setting change is completed!
Protocol setting
5. CONSTRUCTION
5.1 Indoor Speed Dome Camera
Dome Camera mounting base
AC24VInput
Video Output
RS485data
Dome Housing (twists off
anti-clockwise to access fixing
positions.
Camera