COOLING SYSTEM 

•  This Water Cooler unit does not use a compressor or chemical refrigerant for cooling (as 

used in a typical fridge at home). It has a Thermoelectric Cooling (TEC) System instead. 

•  Thermoelectric Cooling (TEC) uses a Peltier effect to create a heat flux between the 

junctions of two different types of materials. 

•  A Peltier cooler is a solid-state active heat pump which transfers heat from one side of 

the device to the other side against the temperature gradient (from cold to hot), when 
power is supplied. 

•  Such an instrument is also called a Peltier Device, Peltier Diode, Peltier Heat Pump, Solid 

State Refrigerator, or Thermoelectric Cooler (TEC). 

THE ADVANTAGES OF TEC

 

•  Thermoelectric coolers have no compressor. 
•  No Freon or other liquid or gaseous refrigerants required. 
• Quiet operation. 
• Very low power consumption. 
• Compact size and light weight makes TEC well suited for miniature coolers. 
• High reliability – can work many hours with no failures. 
• Relatively low cost and high effectiveness. 

TYPICAL WATER COOLING RESULT

 

It will take approximately 30 - 40 minutes to cool (depending on ambient temperature) 
600ml of filtered 22˚C water when first switching the unit ON. 

 

BEFORE FIRST USE

• Wash and rinse out the plastic water tanks thoroughly before use. 
•  Remove the filter from its packaging then fully cover and soak in cold clean water for 

30 minutes and then rinse off under cold clean running tap water. 

•  You may notice a fine black dust come out of the filter. This will happen on all new 

filters and when water is filtered through it the first couple of uses. This is no cause for 
alarm. It is just the dust from the activated carbon inside the filter. Although it looks 
unsightly, it will not harm you. 

•  Place Lower Water Tank and Upper Water Tank onto the cooler. 
•  Insert filter and ensure it sits flat and fully seated. 

 
• Fill Upper Water Tank with clean cold water. 
•  As a reminder of when to change and replace the filter, lift and turn the dial on the lid 

to the current month. The filter replacement month will show the second successive 
month from the start date. 

 
• Place the lid on the Upper Water Tank. 
•  Let the water filter through into the Lower Water Tank and continue to refill the Upper 

Water Tank until both the top and lower water tanks are full. 

•  It is recommended that for first use and each time the filter is subsequently changed, 

the tap is opened to allow all the water to flush through and to remove any remaining 
black dust. Repeat a second time. The discarded water can be used on your plants 
without harm. 

•   Please 

DO NOT

 fill above the maximum fill line as water will flow out between the two 

water tanks and make a mess on your work surface. 

Fill with cold 

water to the 

Max Fill line on 

the Upper Water 

Tank approx. 

1.8L

Water will drip 

through the filter 

into the Lower 

Water Tank 

approx. 2.6L

Orange light – 

power on when 

illuminated

Blue light –  

water cooling 

when illuminated

Water Filter

Water Filter

Date Indicator for filter replacement

Upper 

Water Tank

Filtered water 

will flow into the 

internal Cooler 

Water Tank 

approx. 600ml

It will take approximately 30 - 40 minutes to cool 600ml 

of filtered water when you first switch on the unit

2