While one person holds fixtures in place check to make sure 
fixture is level. DO NOT WALK AWAY LEAVING THE FIXTURES 
UNFASTENED BY MECHANICAL MEANS. Fixture can be leveled 
via grip lock on opposite end of fixture. Once fixtures are flush 
to one another and level install torx head screw through cast 
joiners to snug fixtures together. DO NOT OVER TIGHTEN. Torx 
screw will pull fixtures together tightly without too much force.

Replace all access plates and move lenses back to proper 
positions. The fixture installation is now complete

10

Torx Screw

Summary of Contents for Neo-Ray Define S122 IP

Page 1: ... the improper careless or negligent installation handling or use of this product IMPORTANT Read carefully before installing fixture Retain for future reference NOTICE Green ground screw provided in proper location Do not relocate NOTICE Fixture may become damaged and or unstable if not installed properly Note Specifications and dimensions subject to change without notice ATTENTION Receiving Depart...

Page 2: ...plate by slidinng the lens out of the way andremoving two 8 32 screws Pull aircraft cable through griplocks and adjust to desired height Make sure to level the fixture correctly applies to individuals or first piece in row Parts List Fixture Access Plate Push In Connectors Cast Joiner Torx Screws Additional 8 32 Phillips Screws Phillips Screw Driver Bit 6L T15Torx Screwdriver Bit Rubber Mallet T 1...

Page 3: ...n the row using the griplock and pre installed aircraft cable Temporarily support the other end Ensure the alignment pins and cast joiners are seated correctly in the adjoining fixture FOR CONTINUOUS ROWS ONLY Hang far end of the next fixture in the row using the griplock and pre installed aircraft cable Temporarily rest adjoining fixture on the first and join dimming and power wires using the pro...

Page 4: ...VINGTHE FIXTURES UNFASTENED BY MECHANICAL MEANS Fixture can be leveled via grip lock on opposite end of fixture Once fixtures are flush to one another and level install torx head screw through cast joiners to snug fixtures together DO NOT OVERTIGHTEN Torx screw will pull fixtures together tightly without too much force Replace all access plates and move lenses back to proper positions The fixture ...

Page 5: ...device must accept any interference received including interference that may cause undesired operation Note The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance Such modifications could void the user s authority to operate the equipment Note The equipment has been tested and found to comply with the limits for a Class B digi...

Reviews: