Installation Instructions – Define S122-125 Suspended LED Luminaire
Installation Instructions – Define S122-125 IP
INSTALLATION
Define DP/RDP/DIP/RDIP
(2”- 5” Housing Size)
Individual and Continuous Luminaires - Installation
Turn off power before installation. Connect mounting kits at
pre-specified locations according to your specific ceiling type
(see submittal for dimensional details). Remove fixture from
box and remove access plate by slidinng the lens out of the way
andremoving two #8-32 screws.
Pull aircraft cable through griplocks
®
and adjust to desired
height. Make sure to level the fixture correctly (applies to
individuals or first piece in row).
Parts List
•
Fixture
•
Access Plate
•
Push In Connectors
•
Cast Joiner & Torx Screws
•
Additional 8-32 Phillips Screws
•
Phillips Screw Driver (Bit)
•
6L – T15 Torx Screwdriver (Bit)
•
Rubber Mallet
•
T-15 Torx Joining Screws (2 per row
fixture connection)
•
#8-32
Joining Bracket Screws (2 per
row fixture connection)
Cross Section and Grid Spacing Details
X
V
1
2
IP
All Grid
X
Define 2
4.132
2.000
Define 3
4.567
3.000
Define 4
5.132
4.000
Define 5
5.632
5.000
V