background image

Panel fire/fault indicators

Specification

9

Normal condition

--------

Zone wiring open/short

--------

Zone disabled

--------

Sounder cct. disabled

--------

Sounder and zone cct. disabled

--------

Power supply fault

--------

Sounder circuit open/short

--------

Panel in test

--------

System fault

Panel button pressed

--------

Battery open circuit/reverse polarity

--------

Battery high/low voltage

Fire

Evacuation

Gener

al f

ault

Fire

Disab

le

P

o

w

er On

Charger f

ault

System f

ault

Disab

le/F

ault z

one

Disab

le/F

ault

counder cct

T

est

Buzz

er

Panel type

1 Zone

2 Zone

4 Zone

8 Zone

Detection zones

1

2

4

8

Detectors per zone

32

Alarm lines

2

4

Max. alarm line load

300mA total (shared)

800mA total (shared)

500mA per alarm line

2A total

Fire/Fault relay

Yes

Aux. DC output

No

Special order

24v DC Fused 30mA

Mains input voltage

230v AC - 10% + 15%

System operating voltage

24v DC

Battery

1 x 12v/2.1Ah

1 x 12v/3.2Ah

2 x 12v/3.2Ah

Recharge period

24 hours

Repeater output

No

Special order

Yes

Environmental rating

IP30. -5°C to 40°C Humidity 75% max (NC)

Dimensions

260(w) x 212(h) x 72(d)

332(w) x 270(h) x 90(d)

LED flashing

LED illuminated

Internal buzzer intermittent

Internal buzzer steady

--------

Indication

Situation

Summary of Contents for FX range

Page 1: ...Installation and user manual for the FX range of fire panels 1 2 4 and 8 zone panels...

Page 2: ...el installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check 8 Commissioning User information Maintenance Tables Sounder and Visual Indication 9 Technical S...

Page 3: ...m Within the panel the mains supply should be isolated from the zone and alarm line wiring and should be connected to the terminal block marked MAINS Battery connection The 1 2 4 zone panel requires a...

Page 4: ...oved This range of control panels can support up to 32 detectors max per zone and an unlimited number of call points per zone Sounder wiring The standard 1 2 and 4 zone fire alarm control panels have...

Page 5: ...2 then silence then reset check all indicators show momentarily Check each zone and alarm line for open and short circuit fault monitoring Zone circuits Disconnect the mains and battery supply wire in...

Page 6: ...s the panel indicators and resets faults relay access code level 2 There are 2 access codes used by the control panel access level 2 client code 3112 and access level 3 engineers code These codes are...

Page 7: ...l times until sounder LED turns off Push button to confirm enable sounders 3 1 2 5 Disable zone Isolates required detection zone from the system access code level 2 3 1 2 5 1 2 3 4 5 1 2 3 4 5 Detecto...

Page 8: ...ad by activating a call point Log test results in log book Six monthly Test As per quarterly test Visual inspection of site to check for compliance of system to recommendations of local standard The t...

Page 9: ...el type 1 Zone 2 Zone 4 Zone 8 Zone Detection zones 1 2 4 8 Detectors per zone 32 Alarm lines 2 4 Max alarm line load 300mA total shared 800mA total shared 500mA per alarm line 2A total Fire Fault rel...

Page 10: ...PINSTFX2200GENR1 PR000 00 513 01...

Reviews: