background image

11

11

11

11

11

Cooper Crouse-Hinds GmbH

GHG   64  _    _ _   _ _    R _ _ _ _

Herstellerkennzeichnung

Manufacturer code

Ex-d Leergehäuse

Ex-d enclosure

Verwendung nach Kategorie

Use by category

1

= II B

2

= II B + H2

Leergehäuse

empty enclosure

Größe:

Höhe

x

Breite

x

Tiefe (in mm)

Size:

high

width

depth

01

210

x

210

x

191

02

210

x

320

x

191

03

210

x

320

x

284

04

320

x

320

x

191

05

320

x

320

x

284

06

320

x

430

x

191

07

320

x

430

x

284

08

430

x

430

x

284

09

430

x

650

x

284

10

430

x

650

x

437

11

650

x

650

x

442

10.1

Anhang Typenschlüssel

Annex Type Code

Annex Type Code

Varianten

variants

10

Technischer Anhang

Summary of Contents for CEAG GHG 64

Page 1: ...XNFLMX YDOVWV YDORG YDUDW SLHSUDV W MXVX YDOVWV DWELOG JDM RRSHU URXVH LQGV S UVW YQLHF E 0 LVWJ X MLWROEX GDQ LO PDQZDO ILO OLQJZD QD MRQDOL WDJ KRP PLQJ DQG LU UDSSUH HQWDQW WD RRSHU URXVH LQGV I SD...

Page 2: ...lverschluss 5 6 4 Inbetriebnahme 6 7 Instandhaltung Wartung 6 8 Reparatur Instandsetzung 6 9 Entsorgung Wieder verwertung 6 10 Technischer Anhang 10 1 Anhang Typenschl ssel 11 Contents Contents 2 1 Te...

Page 3: ...60 C f r Kategorie IIB g ltig f r alle Gr en 55 C bis 55 C bei Einsatz in Zone 21 22 Zul Lagertemperatur in Originalverpackung 50 C bis 80 C Schutzart nach EN IEC 60529 IP65 IP66 mit Dichtung im Geh u...

Page 4: ...geh use aus Leichtmetall GHG 64 Fig 1 Geh useoberteil mit optionaler Dichtung Bei einem Einsatz in extrem aggressiver Atmosph re k nnen Sie zus tzliche Informa tionen ber die Chemikalienbest ndigkeit...

Page 5: ...betrachtet Unsachgem e Installation der Ger te f hrt zum Verlust der Garantie 6 3 Schlie en des Ger tes Deckelverschluss Alle Fremdk rper aus dem Ger t Alle Fremdk rper aus dem Ger t Alle Fremdk rper...

Page 6: ...m ssen glatt und unverkratzt sein Anschlie end die Spaltfl chen wieder gleichm ig mit Fett bestreichen Fetttyp Renocal Unitemp 2 50 C bis 100 C FN 745 94 DIN VW TL 745 Sch den an Teilen der druckfeste...

Page 7: ...C for Zone 21 22 Other temperatures possible with special versions Perm ambient temperature in original packing 50 C to 80 C Degree of protection to EN IEC 60529 IP54 IP66 with seal Insulation class t...

Page 8: ...uding any external metal parts are high quality materials that ensure a corrosion resistance and resistance to chemical substances according to the requirements for use in a normal industrial atmosphe...

Page 9: ...closures with or without switches it is necessary to ensure that there is no voltage or to take suitable protective measures The connection of explosion protected Ex d enclosures and distributions may...

Page 10: ...operator according to the respective operating conditions Special attention should be given to ensuring Integrity and tightness of the enclosure Integrity of the flameproof joints on the enclosure bod...

Page 11: ...H2 Leergeh use empty enclosure Gr e H he x Breite x Tiefe in mm Size high width depth 01 210 x 210 x 191 02 210 x 320 x 191 03 210 x 320 x 284 04 320 x 320 x 191 05 320 x 320 x 284 06 320 x 430 x 191...

Page 12: ...use Hinds GmbH Neuer Weg Nord 49 D 69412 Eberbach Germany Fone 49 0 6271 806 500 Fax 49 0 6271 806 476 Internet www ceag de E Mail sales cch de cooperindustries com GHG 640 7003 P0001 D E F b Auflage...