Cooper Sound CS306 Operator'S Manual Download Page 16

1. 

Warranty registration must be completed and mailed to Cooper Sound Systems, Inc. within

30 days of the date of purchase.

2. 

Cooper Sound Systems, Inc. warrants the materials and workmanship of this product for a

period of one year from the original date of purchase.  If any defects are found in 
the materials or workmanship, or if the product fails to function properly (as per the
specifications out-lined in the Operator’s Manual) within the specified warranty 
period, Cooper Sound Systems, Inc. will repair or replace the product, at its option.

Please note the following:

A.

Modifications made by the customer or a non-authorized service center will invalidate the warranty.

B.

Damage caused to the unit by incorrect or improper usage (eg; utilization of incorrect power supply

or other improper connections) is not covered under this warranty.

C. 

To obtain factory service, call: Cooper Sound Systems, Inc. (805) 772-1007 or FAX (805) 772-1098

D.

All returns and service requests must have prior authorization.

E.

Cooper Sound Systems, Inc. reserves the right to inspect any product which may be the subject of

any warranty claim, before repair or replacement is carried out.  Cooper Sound Systems, Inc. may,

at its option, require proof of the original date of purchase (dated copy of original retail dealer’s 

invoice). Final determination of warranty coverage lies solely with Cooper Sound Systems, Inc. 

Products which do not meet the terms of this warranty will be repaired and returned C.O.D. with 

billing for labor, materials ,return freight and insurance.  Products repaired under warranty will be 

returned via U.P.S. ground, freight prepaid, by Cooper Sound Systems, Inc. to any location within

the boundaries of the U.S.A.  Outside the U.S.A., the products will be returned freight collect.

F.

This warranty is extended to the original purchaser, and to anyone who may subsequently purchase

this product within the specified warranty period.

G.

Cooper Sound Systems, Inc. does not authorize any third party, including any dealer or sales 

representative to assume any liability on behalf of Cooper Sound Systems, Inc., or to make any 

warranty for Cooper Sound Systems, Inc.

H.

The above warranty is the only warranty given by Cooper Sound Systems, Inc. and is in lieu of all

other warranties.  All implied warranties, including warranties of merchantability or fitness for any 

particular purpose shall be strictly limited in duration to one year from the date of original purchase.

Upon the expiration of the warranty period (one year), Cooper Sound Systems, Inc. shall have no 

further warranty obligation of any kind, expressed or implied.  Cooper Sound Systems, Inc. shall in

no event be obligated for any incidental or consequential damages that may result from any defect,

or warranty claim of any kind, expressed or implied.

I.

Cooper Sound Systems, Inc. reserves the right to modify the design of the equipment and to amend

specifications without prior notice.

14

June 2006

Left Page
Left Page

LIMITED WARRANTY

MODEL CS306

Summary of Contents for CS306

Page 1: ...645 Main Street Suite C Morro Bay CA Phone 805 772 1007 Fax 805 772 1098 http www coopersound com 93442 2273 USA CS306 PROFESSIONAL AUDIO MIXER OPERATOR S MANUAL...

Page 2: ...CRIPTION 1 OUTPUT MODULE DESCRIPTION 2 REAR PANEL DESCRIPTION 3 BLOCK DIAGRAM 4 STEREO MODULE OPTIONAL 5 PIN OUTS 6 SPECIFICATIONS SPECIFICATIONS 7 8 OPERATION APPLICATION NOTES 9 10 APPLICATION NOTES...

Page 3: ...s filter see specs 4 O L Near overload indicator 5 PFL Pre fade listen 6 9 A B C D Channel to mix bus assigns L left R right indicate monitor pan pot assignment center position is off 10 LIM LED The l...

Page 4: ...mic gain adjustment 14 TAPE DIR monitor 1 Tape or Direct to Monitor 1 15 M ST MS monitor 1 M mono ST stereo MS mid side Any combination selected by switches 16 19 can be monitored in mono stereo or m...

Page 5: ...ape returns AB in out CD in out 6 COMM In Communications input to Monitor 1 balanced line level 7 ROLL Remote control for various recorders 8 ACC Not used Machined for a DB9 connector 9 Unbalanced out...

Page 6: ...L comm PL ABCD monitor 2 dir tape drivers batt test returns Meters DB25 CS306 block diagram mic line 4dBu AB out only DB25 CH 7 8 pre amp HP1 2 channel fader OL Lim A B C D PFL xfmer driver dir tape r...

Page 7: ...l fader is disconnected from the circuit Link on also links the two limiters 2 MS DEC MS Decode The even channel output is inverted to bus B only Both pan pots should be centered With equal gain the M...

Page 8: ...DB9 1 Ground 6 B D in 2 A 3 B 7 A C in 4 C 8 A C in 5 D 9 Ground 10 Ground Roll See application note Channel Outputs DB25 TQG 5M Pin 1 10 v Nagra Pin Pin Pin 2 Stop Nagra Ch 1 Hot 24 Ch 5 Hot 18 Pin 3...

Page 9: ...cells Consumption 500 mA at 12v DC 6 watts Estimated battery life with NP1 Nicad 4 5 hours NP1 Nmh 7 5 hours 8 AA alkaline cells 3 5 hours Nicad AA cells are 1 3 the capacity of alkaline cells Battery...

Page 10: ...PM 0 VU XLR s are Pin 2 high XLR 10 pin balanced outputs A B C D 4 dBu Zout 100 DB 9 unbalanced outputs A B C D 2 dBu Zout 100 Monitor 1 out 0 dBu no load 0 dBu 60 load Maximum load is 25 for each out...

Page 11: ...the average program level will modulate the meter to 0 dB During the take the channel fader may be used for controlling the channel gain O L LED Nominally set for 3 dB below M O L maximum output leve...

Page 12: ...witch to internal when using batteries It is recommended to use alkaline AA cells Rechargeable Nicad cells may be used with reduced battery life Pin 3 of power XLR is the positive charger input Pin 1...

Page 13: ...however we recommend wiring pin 1 as negative to remain consistent with earlier versions see Layouts Default Momentary to rear of mixer Nagra 1V Nagra V HHB PD2 4 6 portadat 2 6 1 5 latch latch 5 3 mo...

Page 14: ...communications input can be used with multiple inputs eg two boom operators by using a special adapter cable see below The communication in connector is balanced Pin 2 high Pin 3 low Pin 1 ground The...

Page 15: ...rminate RF option The Shield is connected at the source only to avoid ground loops Notes 1 2 3 Unbalanced out to balanced in option R out R out Impedance matched for better common mode rejection R out...

Page 16: ...nc Products which do not meet the terms of this warranty will be repaired and returned C O D with billing for labor materials return freight and insurance Products repaired under warranty will be retu...

Page 17: ...NOTES NOTES MODEL CS306 15 June 2006...

Reviews: