www.cooperbussmann.com/BussmannWirelessResources
Cooper Bussmann Wireless Ethernet & Device Server BU-945U-E 802.11 DSSS User Manual
21
3A1582Rev1.6
Method 1 - Set PC to same network as BU-945U-E
Connect the Ethernet cable between unit and the PC configuring the module.
• Set the Factory Default Switch to the SETUP position. This will always start the BU-945U-E with Ethernet IP address 192.168.0.1XX, subnet
mask 255.255.255.0, gateway IP 192.168.0.1 and the radio disabled.
Do not forget
to set the switch back to the RUN position and restart the
module at the conclusion of configuration for resumption of normal operation.
• Power up the BU-945U-E module.
• Open “Network Settings” on your PC under Control Panel. The
following description is for Windows XP - earlier Windows
operating systems have similar settings.
• Open “Properties” of Local Area Connection.
• Select Internet Protocol (TCP/IP) and click on Properties.
• On the General tab enter IP address 192.168.0.1, Subnet mask
255.255.255.0 and press “OK”
• Open Internet Explorer and ensure that settings will allow you to
connect to the IP address selected. If the PC uses a proxy server,
ensure that Internet Explorer will bypass the Proxy Server for local
addresses.
• This option may be modified by opening Tools -> Internet Options -
> Connections Tab -> LAN Settings->Proxy Server -> bypass proxy
for local addresses.
• Enter the default IP address for the BU-945U-E 192.168.0.1XX
where XX is the last two digits of the serial number.
• Enter the username “user” and default password “user.”
Figure 1