Service diagnosis
2
8
Domestic air conditioner
10.3 Error Codes and Description indoor display
Code indication
fault description
Reference
Page
Indoor
displaying
panel code
indication
Outdoor
(LED1 flash
times)
Indoor
and
Outdoor
E7
15
Communication fault between indoor and
outdoor units
Page .39
Indoor Malfunction
E1
--
Room temperature sensor failure
Page 28.
E2
--
Heat-exchange sensor failure
Page 28.
E4
--
Indoor EEPROM error
Page 29.
E14
--
Indoor fan motor malfunction
Page 30
Outdoor
Malfunction
F12
1
Outdoor EEPROM error
Page .29
F1
2
The protection of IPM
Page .33
F22
3
Overcurrent protection of AC electricity
for the outdoor model
Page .34
F3
4
Communication fault between the IPM and
outdoor PCB
Page.36
F19
6
Power voltage is too high or low
Page .37
F4
8
Overheat
protection
for
Discharge
temperature
Page .38
F21
10
Defrost temperature sensor failure
Page 28.
F7
11
Suction temperature sensor failure
Page .28
F6
12
Ambient temperature sensor failure
Page .28
F25
13
Discharge temperature sensor failure
Page .28
F11
18
deviate from the normal for the compressor
Page .41
F28
19
Loop of the station detect error
Page .41
F2
24
Overcurrent of the compressor
Page .34
F23
25
Overcurrent protection for single-phase of the
compressor
Page .40
Summary of Contents for TERRA CH-S09FHCP
Page 12: ...Piping diagrams Domestic air conditioner 5 Piping diagrams 10 ...
Page 14: ...Printed circuit board connector wiring diagram 12 Domestic air conditioner PCB ...
Page 49: ... ...
Page 50: ... ...
Page 51: ... ...
Page 52: ... ...
Page 53: ... ...
Page 54: ... ...
Page 55: ... ...
Page 56: ... ...
Page 57: ... ...