77
76
Removal Procedure
Removal Procedure
12. Remove 4-way valve assy
13. Remove isolation sheet
Remove the screws fixing the isolation sheet
and then remove the isolation sheet.
Warning
Discharge the refrigerant completely before
unsoldering,when unsoldering, wrap the gas
valve with awet cloth completely to avoid
damage to thevalve caused by high
temperature.
Unsolder the spot weld of 4-way valve assy,
compressor and condenser, and then remove
the 4-way valve assy .
When unsoldering the spot weld, wrap the
4-way valve with wet cloth completely to avoid
damaging the valve due to high temperature.
4-way valve assy
Isolation sheet
Screw
Note
Procedure
14. Remove the compressor
B: Remove the foot nuts on the compressor
and then remove the compressor.
Liquid valve
A: Remove the 2 screws fixing the gas valve
and unsolder the welding joint between the
gas valve and the air-return pipe to remove
the gas valve.
14. Remove Expansion valve Assy
Unsolder the spot weld of expansion valve
assy, liquid valve and condenser, and then
remove the expansion valve assy .
Expansion valve Assy
Gas valve
Compressor
Note
Procedure