background image

Model/modèle :MPPDB-09HRN1-BCG5

Summary of Contents for MPPDB-09HRN1-BCG5

Page 1: ...Model mod le MPPDB 09HRN1 BCG5...

Page 2: ...ty Precautions 3 Cautions 4 Installation 5 Operation 9 Maintenance 14 Faults Diagnosis 15 Design and Compliance Notes 16 Sociable Remark 17 Remote Controller Illustration 18 Air Conditioner Limited Wa...

Page 3: ...swing automatically Caster rear power plug socket power cord buckle bottom tray drain outlet power cord outlet drain outlet only for pump heating mode upper air filter behind the grille upper air int...

Page 4: ...room Too much exposure to water can cause electrical components to short circuit DO NOT install the unit in a location that may be exposed to combustible gas as this could cause re The unit has wheel...

Page 5: ...d persons in order to avoid a hazard Prior to cleaning or other maintenance the appliance must be disconnected from the supply mains Do not install the appliance in a location that may be exposed to c...

Page 6: ...r speci c information on the type of gas and the amount please refer to the relevant label on the unit itself Installation service maintenance and repair of this unit must be performed by a certi ed t...

Page 7: ...seat of the air outlet and slide down the Exhaust hose assembly along the arrow direction for installation Step Two Install the Exhaust hose assembly to the unit Part Description 1 pc 1 pc 1 pc 1 pc...

Page 8: ...gths and attach them to the window sash and frame as shown Insert the window slider assembly into the window opening Insert the window slider adaptor into the hole of the window slider Cut the non adh...

Page 9: ...the window frame to prevent airand insects from getting into the room Type 2 Sliding Window Installation Note To ensure proper function DO NOT overextend or bend the hose Make sure that there is no o...

Page 10: ...ttons Used to adjust increasing decreasing temperature settings in 1 C 1 F increments in a range of 17 C 62 F to 30 C 86 F or the TIMER setting in a range of 0 24hrs NOTE The control is capable of dis...

Page 11: ...ature The temperature can be set within a range of 17 C 30 C 62 F 86 F Press the FAN SPEED button to choose the fanspeed COOL operation Operation Instructions Press the MODE button until the DRY indic...

Page 12: ...iginally programmed SLEEP ECO operation When the unit is on press the Timer button will initiate the Auto off stop program the TIMER OFF indicator light illuminates Press the UP or down button to sele...

Page 13: ...ng modes remove the upper drain plug from the back of the unit install the drain connector 5 8 universal female mender with 3 4 hose locally purchased For the models without drain connector just attac...

Page 14: ...emove the bottom drain plug and let the water drain away Reinstall the bottom drain plug and restart the machine until the P1 symbol disappears If the error repeats call for service NOTE Make sure the...

Page 15: ...r ow due to animal hair Safety Precautions Clean the unit using a damp lint free cloth and mild detergent Dry the unit with a dry lint free cloth Clean the Unit Drain the unit s water collection tray...

Page 16: ...theflow of refrigerant insidethe unit The air filter is blocked withdust or animal hair The air filter is blocked withdust or animal hair Turn off the unit and clean thefilter according to instruction...

Page 17: ...r notice Design Notice The Energy Rating for this unit is based on an installation using an un extended exhaust duct without adapters A or B as shown in the Installation section of this manual Energy...

Page 18: ...st free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least f...

Page 19: ...ated Voltage 8m 3 0V Dry batteries R03 LR03 2 Environment Signal Receiving Range RG57H B BG C E RG57H3 B BG C EF RG57H1 B BG C E M RG57H B BG C EU1 RG57H1 B BG C E RG57H2 B BG C EF Remote Control Spec...

Page 20: ...s temperate in O O 1 C 1 F increments Min temperature is O O 17 C 62 F TIMER ON Sets timer to turn unit on see How to Use Basic Functionsfor instructions TIMER OFF Sets timer to turn unit off seeHow t...

Page 21: ...ains other materials and direct sunlight can interfere with the infrared signal receiver Remove batteries if the remote will not be used more than 2 months Inserting and Replacing Batteries Your air c...

Page 22: ...ery display SILENT display ECO display Displays when SLEEP function is activated FAN SPEED display Displays selected FAN SPEED HIGH MED or LOW This display is blank when set to AUTO speed Temperature...

Page 23: ...ect the COOL FAN HEAT or DRY mode based on the set temperature 1 Press the MODE button to select Auto mode 2 Set your desired temperature using the Temp or Temp button 3 Press the ON OFF button to sta...

Page 24: ...PEED can t be changed in DRY mode 1 Press the MODE button to select FAN mode 2 Press FAN button to select the fan speed AUTO LOW MED or HIGH 3 Press the ON OFFbutton to start the unit NOTE You can t s...

Page 25: ...button to select the fan speed AUTO LOW MED or HIGH 4 Press the ON OFF button to start the unit NOTE As outdoor temperature drops the performance of your unit s HEAT function may be affected In such...

Page 26: ...to turn on For example if you set TIMER ON for 2 hours will appear on the screen and the unit will turn on after 2 hours Press the TIMER ON button By default the last time period that you set and an h...

Page 27: ...n to the temperature display Example hours Setting unit to turn off after 5 TIMER OFF function The TIMER OFF function allows you to set a period of time after which the unit will automatically turn of...

Page 28: ...the current time For example say that the current time is 1 00 PM and you want the unit to turn on automatically at 7 00 PM You want it to operate for 2 hours then automa tically turn off at 9 00 PM D...

Page 29: ...s then turn off see the figure below Your remote display Timer is set To turn ON 6 hours from current time Timer is set to turn OFF 8 hours from current time Current time 1PM 2PM 3PM 4PM 5PM 6PM 7PM 8...

Page 30: ...ating mode setting temperature fan speed level and sleep feature if activated Used to stop or start louver movement and set the desired up down air flow direction The louver changes 6 degrees in angle...

Page 31: ...found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residenti...

Page 32: ...31 31...

Page 33: ...MPPDB 09HRN1 BCG5...

Page 34: ...n garde 4 Installation 5 Fonctionnement 9 Entretien 14 Diagnostic des d faillances 15 Remarques sur la conception et la conformit 16 Remarques environnementales 17 Illustration de la t l commande 18 G...

Page 35: ...ue Roulette Prise de courant Boucle du cordon d alimentation Sortie d vacuation du bac inf rieur Prise pour cordon d alimentation Sortie d vacuation seulement pour le mode pompe chaleur Filtre air sup...

Page 36: ...une buanderie Une exposition trop importante l eau peut entra ner un court circuit au niveau des composants lectriques NE PAS installer l appareil dans un endroit pouvant tre expos aux gaz combustibl...

Page 37: ...d viter tout risque Avant le nettoyage ou l entretien l appareil doit tre d branch du r seau lectrique Ne pas installer l appareil dans un endroit pouvant tre expos aux gaz combustibles L accumulatio...

Page 38: ...os e sur l appareil L installation le service l entretien et la r paration de cet appareil doivent tre effectu s par un technicien qualifi La d sinstallation et le recyclage de l appareil doivent tre...

Page 39: ...la sortie d air et installer l assemblage du tuyau d vacuation en le faisant glisser dans le sens de la fl che tape 2 installation de l assemblage du tuyau d vacuation sur l unit Pi ce Description 1...

Page 40: ...t de fen tre dans l ouverture de la fen tre Ins rer l adaptateur pour battant coulissant de fen tre dans l emplacement du battant coulissant de fen tre Couper la bande C du joint en mousse non adh sif...

Page 41: ...ch ssis de fen tre pour emp cher l air et les insectes d entrer dans la pi ce Type 2 installation pour fen tre coulissante Remarque Pour garantir un bon fonctionnement NE PAS trop tirer ou plier le tu...

Page 42: ...emp rature en incr ments de 1 C 1 F dans une plage de 17 C 30 C 62 F 86 F ou le r glage TIMER dans une plage de 0 24 heures REMARQUE la commande est capable d afficher la temp rature en degr s Fahrenh...

Page 43: ...uton MODE jusqu ce que le voyant COOL s allume Appuyez sur les boutons ADJUST ou pour s lectionner la temp rature ambiante d sir e La temp rature peut tre r gl e dans une plage de 17 C 30 C 62 F 86 F...

Page 44: ...amm Mode SLEEP ECO Lorsque l appareil est sous tension appuyer sur le bouton Timer pour activer le programme Auto off stop et le voyant TIMER OFF s allume Appuyer sur le bouton fl ch vers le haut UP o...

Page 45: ...on du flux d air automatiquement REMARQUE Sur certains mod les l a rateur lames peut tre r gl manuellement seulement Lorsque le syst me est sous tension l a rateur lames s ouvre enti rement Appuyer su...

Page 46: ...r le bouchon de vidange inf rieur puis red marrer l appareil jusqu ce que le symbole disparaisse Si l erreur se reproduit appeler le service d entretien REMARQUE S assurer que le tuyau est connect afi...

Page 47: ...asionn Consignes de s curit Nettoyer l appareil l aide d un chiffon humide non pelucheux et d un d tergent doux S cher l appareil avec un chiffon sec non pelucheux Nettoyer l appareil Vider le bac de...

Page 48: ...il Le filtre air est obstru par la poussi re ou des poils d animaux Le filtre air est obstru par de la poussi re ou des poils d animaux teignez l appareil et nettoyez le filtre conform ment aux instru...

Page 49: ...tion Le rendement nerg tique de cet appareil est en fonction d une installation utilisant un tuyau d vacuation non prolong sans adaptateur A ou B comme indiqu dans la section Installation du pr sent m...

Page 50: ...produit le d taillant reprendra gratuitement votre produit usag C Le fabricant reprendra l appareil usag pour la mise au rebut sans frais pour l utilisateur D tant donn que les produits usag s contie...

Page 51: ...nsion 8 m 3 0V piles s ches R03 LR03 2 Environnement Port e de r ception du signal RG57H B BG C E RG57H3 B BG C EF RG57H1 B BG C E M RG57H B BG C EU1 RG57H1 B BG C E RG57H2 B BG C EF Sp cifications de...

Page 52: ...l appareil se reporter aux instructions de la section Utilisation des fonctions de base TIMER OFF minuterie d sactiv e Pour programmer la minuterie pour teindre l appareil se reporter aux instructions...

Page 53: ...UTILISATION pr vaudra Insertion et remplacement des piles Votre climatiseur comprend deux piles AAA Ins rer les piles dans la t l commande avant d utiliser 1 Glisser le couvercle arri re de la t l com...

Page 54: ...ran ECO S affiche lorsque la fonction de veille est activ e cran VITESSE DE VENTILATION Affiche la vitesse de ventilation s lectionn e HIGH lev MED moyen ou LOW faible Cet cran est vide lorsque la vit...

Page 55: ...ilation HEAT chaleur ou DRY ass chement en fonction de la temp rature r gl e 1 Appuyer sur le bouton MODE pour s lectionner le mode AUTO automatique 2 R gler la temp rature d sir e l aide du bouton Te...

Page 56: ...bouton MODE pour s lectionner le mode FAN ventilation 2 Appuyer sur le bouton FAN ventilation pour s lectionner la vitesse de ventilation AUTO automatique LOW faible MED moyen ou HIGH lev 4 Appuyer s...

Page 57: ...eur 2 R gler la temp rature d sir e l aide du bouton Temp arrow up ou Temp arrow down 3 Appuyer sur le bouton ON OFF allumer teindre pour d marrer l appareil REMARQUE Une baisse de temp rature l ext r...

Page 58: ...ixer une p riode de temps apr s laquelle l appareil s allumera automatiquement par exemple lorsque vous rentrez du travail 1 Appuyer sur le bouton TIMER ON minuterie activ e Par d faut la derni re p r...

Page 59: ...lage pour que l appareil s teigne apr s 5 heures 2 sec x10 ON OFF MODE FAN SHORT CUT TIM ER ON TIM ER OF F TEMP SLEEP 1 3 2 4 TIMER OFF FF 1 sec TIMER OFF 1 Appuyer sur le bouton TIMER OFF minuterie d...

Page 60: ...OFF R glage des fonctions TIMER ON et TIMER OFF en m me temps Prendre note que les p riodes de temps que vous r glez pour les deux fonctions font r f rence aux heures apr s l heure actuelle Par exemp...

Page 61: ...tre t l commande o La minuterie est r gl e pour que l appareil s allume 6 heures apr s l heure actuelle La minuterie est r gl e pour que l appareil s teigne 8 heures apr s l heure actuelle Heure actue...

Page 62: ...t sur ce bouton lorsque la t l commande est activ e le syst me reviendra automatiquement aux r glages pr c dents y compris le mode de onctionnement la temp rature r gl e la vitesse de ventilation et l...

Page 63: ...APPELER AU 30...

Page 64: ......

Reviews: