Operation
Note: When one of the above malfunctions occurs, turn off the unit, and check
for any obstructions. Restart the unit, if the malfunction is still present, turn off
the unit and unplug the power cord. Contact the manufacturer or its service
agents or a similar qualified person for service.
LED display
Shows the set temperature in °C or °F and the Auto-timersettings.
While on DRY and FAN modes, it shows the room temperature.
Shows Error codes and protection code:
E1-Room temperature sensor error.
E2-Evaporator temperature sensor error.
E3-Condenser temperature sensor error (on some models).
E4-Display panel communication error.
P1-Bottom tray is full--Connect the drain hose and drain the collected
water away.If protection repeats,call for service.
-Press the "MODE" button until the "COOL" indicator light comes on.
-Press the ADJUST buttons "+" or "-" to select your desired room temperature. The
temperature can be set within a range of 17°C~30°C/62°F~86°F.
-Press the "FAN SPEED" button to choose the fanspeed.
COOL operation
Operation Instructions
-Press the "MODE" button until the "DRY" indicator light comes on.
-Under this mode, you cannot select a fan speed or adjust the temperature. The fan motor
operates at LOW speed.
-Keep windows and doors closed for the best dehumidifying effect.
-Do not put the duct to window.
DRY operation
-Press the "MODE" button until the "HEAT" indicator light comes on.
-Press the ADJUST buttons "+" or " - " to select your desired room temperature. The
temperature can be set within a range of 17°C~30°C/62°F~86°F.
-Press the "FAN SPEED" button to choose the fan speed. For some models, the fan
speed can not be adjusted under HEAT mode. DRY operation
-Press the "MODE" button until the "DRY" indicator light comes on.
-Under this mode, you cannot select a fan speed or adjust the temperature. The fan motor
operates at LOW speed.
-Keep windows and doors closed for the best dehumidifying effect.
-Do not put the duct to window.
HEAT operation(cooling only models without)