COOLMAY EX3G PLC/HMI All in one Programming manual
27
AD13
R23653
R23673
D8043
R23633
AD14
R23654
R23674
D8044
R23634
AD15
R23655
R23675
D8045
R23635
When 4~20mA,<3.8mA,value is 32760,which is the disconnection value.
2.6.3 Analog input reading 2 (for Main software version 26220)
Thermocouple K (negative temperature), T type, T type (negative temperature) register read values are
shown as below table:
No
K type(negative
temperature)
T type
T type(negative
temperature)
AD0
R23720
R23700
R23740
AD1
R23721
R23701
R23741
AD2
R23722
R23702
R23742
AD3
R23723
R23703
R23743
AD4(Environment
temperature)
R23724
R23704
R23744
AD5
R23725
R23705
R23745
AD6
R23726
R23706
R23746
AD7
R23727
R23707
R23747
AD8
R23728
R23708
R23748
AD9
R23729
R23709
R23749
AD10
R23730
R23710
R23750
AD11
R23731
R23711
R23751
AD12
R23732
R23712
R23752
AD13
R23733
R23713
R23753
AD14
R23734
R23714
R23754
AD15
R23735
R23715
R23755
2.6.4
Analog input reading 3 (for Main software version 26230 and above)
Support FROM instructions or register read directly. Such as: FROM K0 K0 D400 K16 read 16 analog
input, 0~10V.
The register is directly read:
D[8030]~D[8045]
is the output value set for the corresponding type, the
constant scan time is changed to D8059, and it is started by M8039 (version 26232 and above);
NO
Register Value
AD0
D8030
AD1
D8031
AD2
D8032
AD3
D8033
AD4 (environment temp)
D8034
AD5
D8035
AD6
D8036