Page | 23
Cool Energy inverTech Manual v6.6 2020 ©
7.
Pump Control:
Pump work:
=
(Default Demand)
(Pump stops after reaching set temperature)
Pump Auto:
=
(Default Enable)
(PWM control)
Delta temp. set
=
(Default 5c)
(PWM delta control)
8.
Other Settings:
User configure U06:
(Weather Compensation See Pages 25, 26)
Fan Mode:
=
(Default Daytime)
Daytime - Full Frequency Operation
Night (Low Noise)
–
Low Frequency Operation
Low Speed (Full Weather Compensation)
–
Automatically Changes Frequency According to Ambient
Enable heater:
=
(Default Enable)
(AUX. HTG Output)
Enable chassis/crank heater
=
(Default Enable)
Heater Control U07:
Comp.delay:
=
(Default 60min)
(Compressor running time before AUX. HTG control)
Ext.temp. setp:
=
(Default 5c)
(AUX. HTG is triggered below this setpoint)
User configure U09:
Auto Start
=
(Default Enable)
(Restart in previous working condition following power failure)
AmbTempSwitch U10:
Enable Switch:
=
(Default Enable)
(Working mode changes automatically based on ambient temperature)
AutoTemp Switch
Setp:
=
(Default 20c)
(When ambient temperature goes above setpoint working mode changes)
Amb Tem.diff:
=
(Default 4c)
(Differential to change working mode)