Keys Explanation:
Unlocking Keys:
Press the
key for 3 seconds until you hear the audible tone, then release the
key. The backlight of the LCD display will turn on and the key pad is locked with no “lock key display”
symbol
. The key p
ad will automatically lock after 60 seconds, displaying the “lock key display”
symbol
.
Power keys:
By pressing the “power”
key for 3 seconds, the unit can be switched ON and
OFF.
“
”
an
d “
”
keys:
Press to increase and decrease set temperature.
“
M
” key:
Press for inquiry, parameter and password setting.
“
Clock
” key:
Press for timer setting, timer eliminate and clock settings.
Press the
key to save the setting and return to the main screen.
Controller Set-Up
1. Temperature Setting:
Make sure key-pad is unlocked. Press the
“
”
key, “temperature setting will change on the Left
which is the set temperature. Press the
“
”
key again, the displayed temperature will increase.
Press the
“
” key
and the displayed temperature will decrease. The range of water temperature
can be set from 30
°C
(68
°F
) to 60
°C
(140
°F
) (default = 60
°C
(140
°F
)).
NOTE:
•
It is recommended that the maximum setting temperature to 60
°C
2. System Status display values:
Make sure key-
pad is unlocked. Press the “
M
” key and enter into the inquiry panel.
The up and down keys can now be used to view the status of all sensors.
On the state of power on
, press the “
M
” key for more than 3 seconds, until an audible tone is heard
and enter into the setting panel. After pa
rameter set, press the “setting” key again
to adjust each
parameter or the up and down arrows to navigate through the settings. After all parameters set, exit
the setting panel by pressing the power key. Details are shown as follows:
Code
Name
Range
Default
P1
Water tank temperature setting
20
℃
─60
℃
55
℃
Summary of Contents for CE-H17