The following parameters change in the energy saving mode „ECO“:
1. Evaporator ventilating fan works in cycles only.
2. Automatic defrost starts every 12 hours only instead of every
8 hours.
3. The rated value is increased according to pre-set factory values
(from +4
°
C auf +6
°
C factory setting)
Rated value in ECO-mode can be changed by pressing button and
or .
In periods of few or none door openings (closing day, at night, holidays) energy
consumption may be reduced considerably by using this mode.
3.2 Defrosting
All refrigerated counters / saladettes are fitted with a fully automatic defrost
regulation. The parameters for defrost intervals, defrost times etc. are factory pre-
set to the optimum values. Parameters should be changed only exceptionally by a
refrigeration/electric specialist. Parameter lists are available from the
manufacturer.
During defrosting “DEF” lights up on the display. This notifies the defrosting phase
and lights out again when defrosting process has been finished.
All refrigerated counters / saladettes with built-in cooling system evaporate the
condensate automatically.
Attention!
Please make absolutely sure that all GN containers are fitted in the
saladettes cut-out and that the cover is closed when the unit is not used.
Do not pour any cleaning water, other liquids, food particles or similar into
the condensate channel. This would affect the fully automatic defrost and
evaporation function of your refrigerated counter / saladette.
Check regularly if the condensation water flows unobstructed through the
drainpipe.