Clearance:
Be sure to allow for a minimum clearance of 2” (51 mm) between all
sides of the housing and any surface or obstacle, and 6” (152 mm) between the
bottom of the housing and any surface or obstacle. The 4- or 6-hob unit’s internal
fans require up to 140CFM (3.9m
3
/min) free air flow and a maximum (do not exceed)
ambient temperature of 115
o
F (46
o
C).
4-Hob Units (MC14004-200, MC14004-400, MC17004-200, MC17004-400)
Wiring Connection:
Black - Phase A
Black - Phase B
NOTE: For proper operation, an independent, dedicated circuit should be used
in all installations.
ALL WIRING MUST BE PERFORMED BY A LICENSED ELECTRICIAN.
ELECTRICAL CONNECTION
CLEARANCE AND DIMENSIONS
*Feet are adjustable. Height range is 6-8” (152-203 mm)
Blue - Neutral
Yellow/Green - Ground
Exterior Dimensions
Height: 17.2”* (436 mm*)
Width: 25.2” (640 mm)
Depth: 30.4” (772 mm)
Weight: 120 lb. (54.4 kg)
Exterior Dimensions
Height: 17.2”* (436 mm*)
Width: 36” (914 mm)
Depth: 30.4” (772 mm)
Weight: 175 lb. (79.38 kg)
Surface Dimensions
Width: 23.1” (587 mm)
Depth: 25.1” (637 mm)
Surface Dimensions
Width: 33.9” (861 mm)
Depth: 25.3” (643 mm)
Clearances
Front: 2” (51 mm)
Back: 2” (51 mm)
Sides: 2” (51 mm)
Bottom (Housing): 6” (152 mm)
Clearances
Front: 2” (51 mm)
Back: 2” (51 mm)
Sides: 2” (51 mm)
Bottom (Housing): 6” (152 mm)
Brown - Phase C
6-Hob Units (MC21006-200, MC21006-400, MC25506-200, MC25506-400)