MGRL/MGHL SERIES
04/08
20
Reference
MG series terminal connections
1
2
3
4
4A
5
6
7
8
9
10
Control Station
Sensing-edge (S.E.)
Closing door moving
warning signal 24VAC
External Interlock
Stop
Up
Down
Common
Add jumper for
momentary pressure
close
Jump when no external
interlock is connected.
Control panel is wired with momentary pressure open and constant pressure close. By jumping terminal 4 & 4A, the push button will be
momentary pressure open and close. Without jumping terminal 4 & 4A, the radio control will
NOT
be functional.
A one-second delay on reverse is standard.
When the door is closing, pushing the “Open” or “Stop” button will stop the door from moving.
When the door is closing, the radio control transmitter can stop and reverse the door at anytime.