When the condensate box is heated to 140 degrees F at the B3 probe, 220 VAC is
sent from terminal 5 of connector X12 to the condenser valve (Y1) until the
temperature drops.
f
If the “Crisp and Tasty” mode is selected
•
12 VDC is sent from terminal 9 of connector X13 on the Control Board (A10)
to the Dehumidification Valve (M2) to pull the humidity out of the cabinet.
◊
In the light and medium modes (one and two drops in the display) the M2
valve will be energized until the valve is open to approximately 30 and 60
degrees..
◊
In the full mode (3 drops in the display) the M2 valve will be energized
until the valve opens 90 degrees.
g
When the Pre-heat timer counts to 0
•
The alarm sounds until the operator opens the door.
•
The Combi cycle begins and the process starts at 5-b again until the Cook
timer counts to 0.
6
With the combi in the Rethermalization mode with time on the timer, the door closed
and the start icon depressed
a
The front display will include a Thermometer while the unit preheats.
b
The fan circuit is energized
•
Voltage is sent from terminals 7 and 9 on connector X14 on the Control Board
to the terminals S and R respectively on the AC drive board for 2 minutes.
◊
The AC drive board ramps up the oven fan motor (M1) Clock wise for 2
minutes.
•
Voltage is removed from the AC Drive for 15 Seconds
•
Voltage is sent from terminals 7 and 8 on connector X14 on the Control Board
to terminals S and F respectively on the AC drive board for 2 minutes.
◊
The AC drive board ramps up the oven fan motor (M1) Counter-clock
wise for 2 minutes.
•
If Voltage is sent from terminal 10 on Connector X14 on the control board to
terminal M on the AC drive board the fan will turn in reduced speed.
•
NOTE:
If the door switch (S7) opens by the door opening, then the fan circuit
is de-energized.
c
The hot air heat circuit is energized
•
220 VAC is sent from terminal 3 of connector X12 on the Control Board
(A10) to the coil of Contactor K4 until the cabinet reaches the set temperature
as sensed at probe B6.
◊
The contactor K4 closes and 220 VAC is sent to the element (E4)
d
The steam circuit is energized
•
220 VAC is sent from terminal 4 of connector X12 on the Control Board
(A10) to the coil of the Y4 solenoid allowing water to be thrown against the
element for 10 seconds every 40 seconds.
e
When the condensate box is heated to 140 degrees F at the B3probe, 220 VAC is
sent from terminal 5 of connector X12 to the condenser valve (Y1) until the
temperature drops.
f
When the Pre-heat timer counts to 0
65
Summary of Contents for Mini Combi with Easy Touch
Page 43: ...42 BACK PANEL ASSEMBLY...
Page 44: ...43...
Page 45: ...44 SINGLE WATER VALVE ASSEMBLY...
Page 46: ...45 DOUBLE WATER VALVE ASSEMBLY...
Page 47: ...46 TIM HORTONS CONTROL PANEL Before S N 1110230000900...
Page 48: ...47 TIM HORTONS CONTROL PANEL After S N 1110 2300 00900...
Page 49: ...47 48 C5118285 ELECTRICAL PANEL ASSEMBLY...
Page 50: ...49 5 WIRE INSERTION VIEW A10 X16 6 CONTROL RELAY BOARD...
Page 51: ...50 TRIM POTS ARE TO BE SET AS SHOWN AC DRIVE BOARD Wire Harness for motor 300772...
Page 52: ...51 OES 6 10 Mini R H Door Assembly C2529771 RH C2527089...
Page 53: ...52 Left Hand Door Assembly C2529775...
Page 54: ...53 FAN MOTOR ASSEMBLY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 16 18...
Page 55: ...54 CONDENSATE BOX 1 2 3 4 6 7 5 8 9 10 11 12 13...
Page 57: ...56 OES 6 10 MINI LIGHT ASSEMBLY...
Page 58: ...57 CLEANING PUMP ASSEMBLY...
Page 59: ...58...
Page 60: ...59...
Page 61: ...60...
Page 62: ...61...