Voltage is sent from terminals 7 and 8 on connector X14 on the Control
Board to terminals S and F respectively on the AC drive board for 2
minutes.
(a)
The AC drive board ramps up the oven fan motor (M1) Counter-clock
wise for 2 minutes.
◊
If Voltage is sent to terminal 10 on Connector X14 on the control board to
terminal M on the AC drive board the fan will turn in reduced speed.
•
The hot air heat circuit is energized
◊
220 VAC is sent from terminal 3 of connector X12 on the Control Board
(A10) to the coil of Contactor K4 until the cabinet reaches the set
temperature (97 C) as sensed at probe B6.
(a)
The contactor K4 closes and 220 VAC is sent to the element (E4)
•
The steam circuit is energized
◊
220 VAC is sent from terminal 4 of connector X12 on the Control Board
(A10) to the coil of the Y4 solenoid allowing water to be thrown against
the element for 25 seconds every 40 seconds.
f
220 VAC is sent from terminals 3 and 4 on connecter X13 on the Control Board
to the Rinse solenoid (Y21) and Rinse Pump (Y20) for 12 seconds.
•
The Rinse cycle is repeated 4 times with the rinse solenoid energized from
terminal 3 on connecter X13 on the control board for 20 seconds on and off
for 40 seconds.
g
For 5 minutes
•
The fan circuit is energized
◊
Voltage is sent from terminals 7 and 9 on connector X14 on the Control
Board to the terminals S and R respectively on the AC drive board for 2
minutes.
(a)
The AC drive board ramps up the oven fan motor (M1) Clock wise for
2 minutes.
◊
Voltage is removed from the AC Drive for 15 Seconds
◊
Voltage is sent from terminals 7 and 8 on connector X14 on the Control
Board to terminals S and F respectively on the AC drive board for 2
minutes.
(a)
The AC drive board ramps up the oven fan motor (M1) Counter-clock
wise for 2 minutes.
◊
If Voltage is sent to terminal 10 on Connector X14 on the control board to
terminal M on the AC drive board the fan will turn in reduced speed.
•
The hot air heat circuit is energized
◊
220 VAC is sent from terminal 3 of connector X12 on the Control Board
(A10) to the coil of Contactor K4 until the cabinet reaches the set
temperature (97 C) as sensed at probe B6.
(a)
The contactor K4 closes and 220 VAC is sent to the element (E4)
•
The steam circuit is energized
◊
220 VAC is sent from terminal 4 of connector X12 on the Control Board
(A10) to the coil of the Y4 solenoid allowing water to be thrown against
the element for 25 seconds every 40 seconds.
67
Summary of Contents for Mini Combi with Easy Touch
Page 43: ...42 BACK PANEL ASSEMBLY...
Page 44: ...43...
Page 45: ...44 SINGLE WATER VALVE ASSEMBLY...
Page 46: ...45 DOUBLE WATER VALVE ASSEMBLY...
Page 47: ...46 TIM HORTONS CONTROL PANEL Before S N 1110230000900...
Page 48: ...47 TIM HORTONS CONTROL PANEL After S N 1110 2300 00900...
Page 49: ...47 48 C5118285 ELECTRICAL PANEL ASSEMBLY...
Page 50: ...49 5 WIRE INSERTION VIEW A10 X16 6 CONTROL RELAY BOARD...
Page 51: ...50 TRIM POTS ARE TO BE SET AS SHOWN AC DRIVE BOARD Wire Harness for motor 300772...
Page 52: ...51 OES 6 10 Mini R H Door Assembly C2529771 RH C2527089...
Page 53: ...52 Left Hand Door Assembly C2529775...
Page 54: ...53 FAN MOTOR ASSEMBLY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 16 18...
Page 55: ...54 CONDENSATE BOX 1 2 3 4 6 7 5 8 9 10 11 12 13...
Page 57: ...56 OES 6 10 MINI LIGHT ASSEMBLY...
Page 58: ...57 CLEANING PUMP ASSEMBLY...
Page 59: ...58...
Page 60: ...59...
Page 61: ...60...
Page 62: ...61...