Appendix A: Labels
App. A - 2
CSMP4030 User Guide
November
2002
Label Category
Description
AUX1…
output
Auxiliary switch 1…
CFMTR
output
Circulating fan motor
CFMTR_SW
input
Circulating
fan motor switch (for monitoring
fan status)
CO2 (CO2A)
input
Carbon dioxide sensor
COSVLV
output
CO2 solenoid valve
CSVLV
output
Cooling solenoid valve
CSW1…
input
Current
switch 1… (for monitoring device
status)
DBDMTR
output
Dehumidification bypass damper motor
DDDMTR
output
Dehumidification drier damper motor
DECFMTR
output
Dehumidification evaporator circulating fan
motor
DECSVLV
output
Dehumidification evaporator cooling
solenoid valve
DEHMVLV
output
Dehumidification evaporator modulating
valve
DEHSVLV
output
Dehumidification evaporator heating
solenoid valve
DHTR
output
Defrost heater
DRIER output
Dehumidification
chemical (desiccant) drier
DRIER_OFF
(SP_DRIER_OFFDLY
)
set point
Dehumidification drier off delay
DRIER_ON
(SP_DRIER_ONDLY)
set point
Dehumidification drier on delay
DSVLV
output
Drain solenoid valve
EDMTR
output
Exhaust damper motor
FLUOR1…
output
Fluorescent lamp 1…
FLUORbnk
output
Fluorescent lamp bank