11
their receivers) which will receive and execute orders coming from a 7392 ECP programmer CASSETTE.
1.
The screen will indicate Zone “1" or “2" or “3". *
2.
With the + or - keys select the zone for that this ECP unit is to control. (Zone 1, 2, 3)
3.
Press “OK” to confirm.
4.
The screen will display the word “EMET” and the zone selected, (Being 1, 2,or 3).
5.
Press “OK” to accept..
*
Note : If using a single zone (Single 7392 ECP transmitter)
You must use Zone 1 one only
At the CASSETTE 7392 RCP Receiver.
Insert each receiver in it’s compartment (Fig.1A)
Each receiver will correspond to the heater unit you wish to control. Make sure that all units you have
installed the receivers are switched to programming mode (Clock mode on selector )
1.
Press and hold the addressing button for 10 seconds until the LED starts flashing. At this
time the receiver has memorized the codes associated with the transmitter that is in EMET
mode.
2.
Press briefly again until the LED stops flashing. This will
confirm that the addressing was accepted by the RCP
CASSETTE.
3.
Repeat this procedure for all the RCP CASSETTES in the
same zone. Remember the cassettes are addressed only when
the transmitter is on “EMET” mode.
4.
Repeat for each zone only when the transmitter for that zone is
in “EMET” mode.
H) Example of a configured zone :
The 7392 ECP CASSETTE Programmer transmits a signal over your homes electrical network. This signal
is the picked up by the RCP receiver CASSETTES. (See Fig. 2B) When the RCP receiver gets this signal it
will set heater MODE. If this heater is linked to other heaters (Via pilot wire) the signal will be re-
transmitted over the pilot wire to the other heaters in that zone. Comfort, economy or frost protection will
control the selected zone. On the heaters themselves, comfort and setback are the only settings that need to
be set individually.
Fig. 2A :
This setup shows 2 ECP CASSETTES (2 zones) and 7 RCP receivers, one RCP per heater
unit. Note : some are configured for zone 1 and some for zone 2.
Fig. 2B :
This setup shows 2 ECP CASSETTES (2 zones) and 2 RCP receivers with 11 heater units.
Note : The RCP heaters are linked with other heaters (Via pilot wire).
Notice:
The bathroom heaters are linked via pilot wire to the RCP heater, this will enable them to
receive the programers orders.
Warning :
Never use more than one 7392 RCP CASSETTE programmer on units that are
linked together with the same pilot wire. Remember to respect the phases for