3
QUICK START
C) Set the program :
1.
Press and hold “MODE” for 2 seconds then press once more briefly.
Day “1" is selected along with “P1", both flashing
2.
To use a preset program use + or - to select the program of your choice. (P1 to P7)
Press “OK” to accept, then it will go to day “2" that will display “P1" and flashing.
Repeat steps 1 and 2 until day ”7"
2.1
For a custom (user defined) program, when your day and “P1" are flashing use + or -
until you see “P=”
Press “MODE”
Now for each hour (1 - 23) use + for Comfort setting and - for Economy setting.
Confirm with “OK” and proceed to the following day.
Repeat this step until day “7"
D) Set the HOME CODE :
1.
Press “MODE” at least 4 seconds (until the “:” disappear)
Press + or - to select the first digit of your 4 digit Home code.
Press “OK” to confirm, proceed to the second digit.
Repeat this step for all digits.
E) Set receivers address :
1.
Press briefly on “MODE”. The transmitter CASSETTE will automatically select Zone “1"
Press “OK” , if you have more than one zone select zone”2" or zone “3" then “OK”.
“EMET” will appear on the screen along with the zone chosen (1 or 2 or 3)
2.
Place the transmitter CASSETTE in the receptacle of the unit, assure that the mode
selector is on programmer mode (clock face Icon)
3.
Place all of the receiver CASSETTES in their appropriate units (Fig.1A), notice the LED
comes on and stays on once the receivers are installed. Place your Convectair units
mode selector on (Clock mode Icon).
4.
On each receiver CASSETTE press and hold the addressing button for 10 seconds until
the LED starts to flash, then press it again briefly until it stops flashing. This will confirm
that the addressing was successful.
5.
Once you are finished with all the CASSETTES in that zone, go to the Programmer
CASSETTE and push “OK” to confirm.The programmer will show the Time & date.
Repeat Step E for each additional zone transmitter.
F) Test time :
•
From the Programmer CASSETTE push on “-/Hgel” for about 4 seconds, then “OK”. The
screen will indicate ”HG:01"
•
During this time verify that all Convectair units are in -/Hgel (frost protection mode). The mode
selection light should have switched to -/Hgel Mode. This may take up to 30 seconds.
•
Return to the Programmer CASSETTE and press on the /Hgel (frost protection mode). The
screen will now indicate the time and day.
•
Once again verify that all Convectair units have switched back to their previous mode.