     MiniWarden Manual                            •                       530-205-4520                           •                             14

The 

TrueDPD

 is an optional accessory that adds a free chlorine measurement. The measurement uses

the DPD method and is not affected by pH, cyanuric acid, saltwater chlorine generators or any other
variables that affect an ORP or amperiometric measurement. It interfaces with the controller using the
TrueDPD connector on the display board (if that connector doesn’t exist use flow switch 2).

Mounting

: Locate  a vertical section of wall space close enough to the controller so that the interface

cable can reach the controller. Attach to the wall with 4 screws. The TrueDPD must be located close to
the flow cell for the 2 foot tube to reach. When ordering the MiniWarden mounted with the TrueDPD it will
be pre-installed as shown in the picture.

When making a measurement, water will flow through the supply tube for about 20 seconds and for fresh
water to reach the sample chamber the supply tube must be as short as possible. Water from the
TrueDPD goes to the drain and does not continuously flow to keep the water fresh. With higher sample
times, the water in the tube will be less representative of the pool water as time goes on until the next
measurement.

Drain

: Attach 1/2” tubing to the drain connection on the front of the TrueDPD flow cell. The tube needs to

be routed through the cable grip near the front bottom center of the box. The tube end should be routed
to a waste drain that is lower than the TrueDPD and should have no obstructions. If there is no drain
then a bucket can be used but it will need to be emptied a couple times a week.

Water In:

 Attach a 1/4” “T” to the exit of the flow cell before the shut off valve. Attach the 1/4” NPT to

barb into the “T”. Route the inlet tube from the TrueDPD and attach to the barb. WARNING: If the
pressure is too high the tube may pop off of the barb fitting. The tube has a barb fitting on the flow cell
and inside the TrueDPD enclosure at the small pump. If inside the TrueDPD damage will occur to the
motors and circuitry. Make sure and use the tube clamps on the supply line.

MiniWarden Interface:

 Connect the red interface wire to the TrueDPD input on the display board and

the black wire to GND. If there is no TrueDPD input connect the red wire to the Flow 2 connector.

Power Supply:

 Plug the power supply into the power source.  The power supply also supports 240 VAC.

If power source is 240 VAC then a suitable plug adapter may be needed. If there is no outlet, a short
extension cord can be used inside the controller enclosure allowing the 12V power supply to reside
inside the enclosure where it has additional protection.

TrueDPD Free Chlorine Sensor - Option

Summary of Contents for MiniWarden

Page 1: ...WARDEN Automated Pool Spa Chemical Controller And Data Recorder ControlOMatic Inc 12659 Arbor Lane Grass Valley CA 95949 530 205 4520 www controlomatic com www poolwardentraining com Manuals also avai...

Page 2: ...N INSTALLATION 8 Mounting MiniWarden 8 Flow Cell To Circulation Plumbing 8 Sensor Wire Connections 10 Supply 110 240 Vac Input Selection 11 Load Equipment Connection Installation 11 Relay Board Acrony...

Page 3: ...ock Disconnect the power until the fault has been identified and corrected 6 It is very important to follow the safety guidelines in this manual to ensure safe installation and programming Safety of a...

Page 4: ...Pool and Spa Chemical Safety 12 1 Never mix sodium hypochlorite and muratic acid 12 2 When mixing acid and water always add acid to the water never add water to the acid 13 CAUTION TEST THE GROUND FA...

Page 5: ...light conditions MEMORY MiniWarden is designed with nonvolatile memory which preserves all internal programming in case of power loss Internal memory is preserved for up to 10 years without having pow...

Page 6: ...mV Free Chlorine PPM With optional TrueDPD sensor NSF Certified Range 0 to 6 0 PPM 10 Free Chlorine PPM Extended non NSF Certified Range 6 0 to 9 5 PPM 20 Certifications NSF ANSI 50 Equipment for Swi...

Page 7: ...er including flow cell sensors and pre mounted on back board MW MTD Add the PW Plus communication module MW FAC Adds free chlorine measurement using the TrueDPD DPD colorimetric method MW FAC Add the...

Page 8: ...s a pressure differential One way to install is to make sure the input source to the flow cell is well upstream from any chemical injection point C Below The Flow cell input and output points before a...

Page 9: ...connection points to the In and Out connection points on the flow cell Once connected turn circulating pump back on test for leaks at all connection points and make sure all air evacuates form the tu...

Page 10: ...the controller and connect as labeled inside MiniWarden or as indicated below in PICTURE 3 Please Note Black wires are always negative and the Clear or Red wires are always positive Flow Sensor Conne...

Page 11: ...ys for pH and ORP are internally connected to the input VAC main input which is located on the left side connector on the circuit board through 5 AMP fuses F1 and F2 No voltage is being supplied to th...

Page 12: ...s Equipment Chlorine Generators A high power chlorine generator should not be powered using MiniWarden s internal VAC power as it may exceed the input 2 5 AMP relay rating One way is to break the chlo...

Page 13: ...ed and off Step 2 Connect the 5 power connector and the interface connector Step 3 Turn the MiniWarden on Step 4 Wait at lease 30 seconds before proceeding Step 5 Press the down arrow from the reading...

Page 14: ...drain connection on the front of the TrueDPD flow cell The tube needs to be routed through the cable grip near the front bottom center of the box The tube end should be routed to a waste drain that i...

Page 15: ...dc 5 TrueDPD Stir MTR TrueDPD Stirring motor assembly 12 vdc 6 TrueDPD Tubing Silicon tubing 1 4 OD x 1 8 ID 7 TrueDPD Flow Cell TrueDPD machined flow cell block 8 TrueDPD Bottle oz Reagent bottle siz...

Page 16: ...r Screen Flow Cell Stainless steel screen for inlet water strainer 7 1250 070 01 Flow Cell 1 4 FNPTxFNTP SMC 2 Way Ball Valves 8 1250 080 01 Flow Cell 1 4 Ball Valve FNPT x MNPT SMC 9 1250 100 01 Flow...

Page 17: ...MiniWarden Manual 530 205 4520 17...

Reviews: