7

SYMPTOM

PROBABLE CAUSE

REMEDY

Door will not operate and:

a) no lights on wall control.

Power point off.

Turn on.

Plug connection loose.

Check the harness connection to
wall control.
Check power plug.

b) SHUTDOWN light on.

Wall Control is in SHUTDOWN mode.

Press SHUTDOWN to turn off.

c) Some lights are flashing.

Refer to page 6.

d) Motor ran but door did not move.

Drive unit DISENGAGED

RE-ENGAGE. See page 3
If lights 6 & 7 flash, press RESET.
If light 2 flashes, press UP.STOP.DOWN
and let the door close fully.

Door operates from wall control but
not from hand transmitter.

Battery in hand transmitter is flat.

Replace battery.

Code not set.

Set code. See page 4.

Transmitter slide switch not in
middle position.

Set slide switch.

Transmitter range varies or is
restricted.

Variations are normal depending on
location and conditions.

See page 2 for correct use.

Battery condition.

Replace as necessary.

Aerial position.

Reposition for maximum range.

Light doesn't operate.

Globe blown.

Check and replace. See page 5.

Door travels too fast.

Power setting may be incorrect.

Call your B&D Dealer.

Door moved upwards a short
distance then closed.

Power has been off.

This is normal sequence
following a power failure, for the unit
to reconfirm its memory.
The door will now operate normally.

Door reverses for no apparent
reason.

This occurs occasionally if the effort
required to operate the door changes
for any reason, such as extreme
changes in weather conditions.

If the problem continues, call your
B&D Dealer.

If problem continues

Door guides damaged.

Repair guides or call your B&D Dealer.

Door reverses off floor.

Controll-A-Door installation problem.

Call your B&D Dealer.

Door roll 'grows large' when closing.

Door not correctly adjusted.

Service door.

Door guides may have excessive
friction.

Clean inside faces of guides.

put oil, grease, sprays of any

kind, polish or talc in the guides.

Do not

Bottom rail weight insufficient.

Call your B&D Dealer.

Door opens on its own.

A neighbour may have the same
transmitter code.

Change your transmitter code and
enter it onto the wall control. See
page 4.

Motor sound changes when the door
is nearly opened.

This is normal on all MPC-3 Controll-A-
Doors on double garage doors.

No cause for concern.

Summary of Contents for MPC-3 MKII

Page 1: ...e read this booklet and keep it in a safe place for future reference WE STRESS THE YOUR B D CONTROLL A DOOR IS NOT A CHILD S PLAYTHING BE AWARE OF WHO MAY USE THE UNIT AND ENSURE THAT IT IS OPERATED W...

Page 2: ...ext time the hand transmitter or UP STOP DOWN is pressed the door will close KEY RING TRANSMITTER L H S BUTTON WALL CONTROL PANEL UP STOP DOWN BUTTON Touch to OPEN or CLOSE door LIGHT BUTTON Touch to...

Page 3: ...ON THE FIRST DOWN MOVEMENT If the door is already closed when UP STOP DOWN is pressed or if there has been a short blackout while you have been out the door will try to go down then go up a short way...

Page 4: ...r limit LIMIT SET MODE LED light will extinguish indicating both limits have been accepted 7 Press UP STOP DOWN button to check the door operation 8 If the limits are not correct finish the sequence t...

Page 5: ...o reconfirm the memory This information will be stored during power failures indefinitely CARE OF THE CONTROLL A DOOR Do not hose the wall unit or drive unit Do not allow gutters to overflow onto the...

Page 6: ...t has cut out due to motor overload Check Correct fault PRESS RESET a Is the door free from obstructions Disengage drive unit and check door manually for smooth operation Door may require service When...

Page 7: ...5 Door travels too fast Power setting may be incorrect Call your B D Dealer Door moved upwards a short distance then closed Power has been off This is normal sequence following a power failure for the...

Page 8: ...ue to or result from i lack of proper maintenance or care of the Unit ii incorrect or unreasonable use iii faulty installation or adjustment of the Unit or door to which the Unit is connected where su...

Reviews: