LIGHTS FLASHING
6
Limits for door travel and Code need
to be set.
LIGHTS
WHAT IS MEANS
WHAT TO DO
Set Limits of door travel and set
Code. See page 4.
Power has resumed after the power
has been off and the door needs to
reconfirm its memory.
Make sure the drive unit is engaged.
Touch UP.STOP.DOWN button or
the Hand Transmitter Button and
allow door to close fully. If the door
is closed, it will move UP a short
way and then close.
The unit has cut out to protect the
motor from overheating, after door
has been operated too frequently.
Wait until No. 4 stops flashing (½
minute) and the green
UP.STOP.DOWN light is on.
Controll-A-Door is now operational.
The unit has cut out due to motor
overload. Check:
Correct fault, PRESS RESET.
a) Is the door free from obstructions?
Disengage drive unit and check door
manually for smooth operation. Door
may require service. When fault has
been corrected, PRESS RESET.
b) Is the door correctly adjusted and
running freely?
Call for Service.
If problem continues and no apparent
fault can be found . . .
The unit has failed to operate. Check:
If so, re-engage drive unit (page 3)
and press RESET.
a) Is the drive unit disengaged?
Unlock. PRESS RESET.
b) Is the centre lift lock locked?
Rectify problem. PRESS RESET.
c) Is the door jammed?
Call for Service.
If problem continues and no apparent
fault can be found . . .
WARNING: THE AUTOMATIC REVERSING SYSTEM WILL NOT OPERATE
FIRST DOWN MOVEMENT!
OFF
ON
ON or
FLASHING
2
FLASHING
FLASHING
UP STOP
DOWN
FLASHING
4
OFF
FLASHING
FLASHING
6
7
OFF
RESET
OFF
RESET
5
7