WebRelay Users Manual
Relay Description
This text is used to describe the function of the relay on the control page. This text will not appear if the
‘Display Relay Status’ is set to
No
, and ‘ON/OFF’ buttons are not displayed which allow relay control.
This field can be up to 20 characters in length.
The following settings are used to set up the way the relay status is displayed.
Note: Be aware that when the WebRelay is used for re-boot purposes, the relay status may or may not
be the same as the device status. When the WebRelay is used to assert the a reset signal on the
motherboard of a server, for example, the relay will be ‘OFF’ most of the time even though the server is
‘ON’ most of the time. The specific re-boot method used should be considered when assigning text and
color to the relay status.
Display Relay Status
When this option is set to
Yes
, the relay status will be displayed on the control page. If it is set to
No
, the
relay status will not be displayed.
Status ON Color
When the ‘Display Relay Status’ option is set to
Yes
, this field specifies the color that will be displayed
when the relay is
on
(coil energized).
Status ON Text
When the ‘Display Relay Status’ option is set to
Yes
, this field specifies the text that will be displayed
when the relay is
on
(coil energized).
Status OFF Color
When the ‘Display Relay Status’ option is set to
Yes
, this field specifies the color that will be displayed
when the relay is
off
(coil not energized).
Status OFF Text
When the ‘Display Relay Status’ option is set to
Yes,
this field specifies the text that will be displayed
when the relay is
off
(coil not energized).
Display Input Status
When this option is set to
Yes
the status of the optically-isolated input will be displayed on the control
page. For most reboot applications, the optically-isolated input will not be used so this should be set to
No
. Note that this input can be used to control a remote relay or be read using the XML page no matter
how this option is set (local relay control is not available in
Automatic Reboot
mode).
Input Description
This is the text that will be displayed next to the input status when the ‘Display Input Status’ is enabled.
This field can be up to 20 characters in length.
Input ON Color
When ‘Display Input Status’ is set to
Yes
, this field specifies the color that will be displayed when the
input is
on
(voltage applied to input).
Input ON Text
When ‘Display Input Status’ is set to
Yes
, this field specifies the text that will be displayed when the input
is
on
(voltage applied to input).
Input OFF Color
When ‘Display Input Status’ is set to
Yes
, this field specifies the color that will be displayed when the
input is
off
(voltage is not applied to input).
Input OFF Text
When ‘Display Input Status’ is set to
Yes
, this field specifies the text that will be displayed when the input
is
off
(voltage is not applied to input).
ON/OFF Buttons