![ControlByWeb WebRelay X-WR-1R12-1I-E User Manual Download Page 50](http://html1.mh-extra.com/html/controlbyweb/webrelay-x-wr-1r12-1i-e/webrelay-x-wr-1r12-1i-e_user-manual_2658788050.webp)
Web Server and Setup Pages
WebRelay Users Manual
Main Header Text
This text will be displayed in the main header area of the control page. This field can be up to 25
characters in length.
Relay Description
This text is used to describe the function of the relay on the control page. This text will not appear if the
‘Display Relay Status’ is set to
No
, the ‘On/Off Buttons’ is set to
0
, and the ‘Pulse Button’ is set to
No
.
This field can be up to 20 characters in length.
Display Relay Status
When this option is set to
Yes
, the relay status will be displayed on the control page. If it is set to
No
, the
relay status will not be displayed.
Status ON Color
When the ‘Display Relay Status’ option is set to
Yes
, this field specifies the color that will be displayed
when the relay is
on
(coil energized).
Status ON Text
When the ‘Display Relay Status’ option is set to
Yes
, this field specifies the text that will be displayed
when the relay is
on
(coil energized).
Status OFF Color
When the ‘Display Relay Status’ option is set to
Yes
, this field specifies the color that will be displayed
when the relay is
off
(coil not energized).
Status OFF Text
When the ‘Display Relay Status’ option is set to
Yes
, this field specifies the text that will be displayed
when the relay is
off
(coil not energized).
ON/OFF Buttons
This option allows the user to specify
0
,
1
, or
2
buttons to turn the relay on or off.
Zero
buttons disables
the users ability to turn the relay
on
and
off
(a pulse button may still be displayed... see below).
One
button may be used to toggle the relay
on
and
off
.
Two
buttons gives the user one button to turn the
relay
on
and another button to turn the relay
off
.
Button 1 Label
When
1
or
2
buttons is selected in the ‘ON/OFF Buttons’ option, this field specifies the text that will be
displayed in pushbutton number 1.
Button 2 Label
When
2
buttons is selected in the ‘ON/OFF Buttons’ option, this field specifies the text that will be
displayed in pushbutton number 2.
Pulse Button
This option allows the inclusion of a pulse button to control the relay. If the pulse button is included, the
relay will
pulse
for the time specified in the ‘Pulse Duration’ field in the ‘Relay/Input’ page each time the
button is pressed.
Pulse Button Label
When the ‘Pulse Button’ option is set to
Yes
, the text entered here will appear in the pulse button on the
control page.
Display Input Status
When this option is set to
Yes,
the status of the optically-isolated input will be displayed on the control
page. Note, the input can be used to control a local relay, a remote relay, or be read using the XML page
no matter how this option is set.