![Control Techniques SM-Encoder Plus User Manual Download Page 20](http://html1.mh-extra.com/html/control-techniques/sm-encoder-plus/sm-encoder-plus_user-manual_2658709020.webp)
20
SM-Encoder Plus User Guide
www.controltechniques.com
Issue Number: 3
Table 6.1 Key to parameter coding
Coding
Attribute
RW
Read/write: can be written by the user
RO
Read only: can only be read by the user
Bit
1 bit parameter
Bi
Bipolar parameter
Uni
Unipolar parameter
Txt
Text: the parameter uses text strings instead of numbers.
FI
Filtered: some parameters which can have rapidly changing values are
filtered when displayed on the drive keypad for easy viewing.
DE
Destination: indicates that this parameter can be a destination parameter.
RA
Rating dependant: this parameter is likely to have different values and
ranges with drives of different voltage and current ratings. This parameters
is not transferred by smart cards when the rating of the destination drive is
different from the source drive.
NC
Not cloned: not transferred to or from smart cards during cloning.
PT
Protected: cannot be used as a destination.
US
User save: saved in drive EEPROM when the user initiates a parameter
save.
PS
Power-down save: automatically saved in drive EEPROM at power-down.