background image

FCC Part 15 Notice 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two con-
ditions: (1) this device may not cause harmful interference, and (2) this device must accept any 
interference received including interference that may cause undesired operation.

FCC Approved Antennas 

This device can only be used with Antennas listed in the Appendix of the SCADAWave JR50 User 
Manual. Please Contact Control Microsystems if you need more information or would like to order 
an antenna.

RF Exposure

To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance  
of 23 cm or more should be maintained between the antenna of this device and persons  
during device operation. To ensure compliance, operations at closer than this distance is not 
recommended. The antenna used for this transmitter must not be co-located in conjunction  
with any other antenna or transmitter.

MAXIMUM EIRP

FCC Regulations allow up to 36 dBm effective isotropic radiated power (EIRP). Therefore, the sum of the 
transmitted power (in dBm), the cabling loss and the antenna gain (in dBi) cannot exceed 36 dBm.

AUSTRALIAN COMPLIANCE NOTICE: MAXIMUM EIRP

ACMA Regulations allow up to 30 dBm (1 Watt) of effective isotropic radiated power (EIRP) in 
the 915MHz license free band and 36 dBm (4 Watts) of EIRP in the 2.4GHz band. Therefore, the 
sum of the transmitted power (in dBm), the cabling loss and the antenna gain cannot exceed the 
above stated EIRP limits.

Contact

www.controlmicrosystems.com

The Control Microsystems web site has links to e-mail and telephone support, technical notes, manuals, and 

software updates.

FCC Compliance Notices

Quick Start Guide

Quick Start Guide - Ultra JR50 Ethernet Data Radio 

15

Summary of Contents for SCADAWave Ultra JR5O

Page 1: ...Quick Start Guide for the Ultra JR50 Ethernet Data Radio This guide provides step by step instructions with simple explanations to get you up and running For further information please refer to the S...

Page 2: ...rating Voltage 10 30 Volts DC Power Supply Protection and Precautions The J Series Radio is supplied with the a mating DC power connector Phoenix Contact Part Number 1777989 The DC Power connector sho...

Page 3: ...cable should be used for installation to comply with ETSI EMC directives Serial Port A B Ports The J Series Radio features a 9 pin miniature D Shell DE 9 Female connector that supports two individual...

Page 4: ...na for Rx Signal When using a directional antenna it will be necessary to align the antenna for the best received signal This can be done using TVIEW Diagnostics or by measuring the RSSI output on Pin...

Page 5: ...g RED LED indicates the REMOTE is not synchronised to a Access Point or BRIDGE Check the antenna all RF connections and the radio configuration as the Subnet ID may not match the Access Point or there...

Page 6: ...IP address of the J Series It is strongly recommended that you follow these guidelines for successful connection to the radio 1 Ensure the J Series is powered up and has fully booted This is indicated...

Page 7: ...k Administrator before allocating IP addresses as each LAN WAN network is different 5 You should start your web browser and insert the IP address of the J Series into the URL In this case we type 192...

Page 8: ...window Checking IP connectivity The most reliable way to check IP connectivity to a device is using the Ping utility Type ping xxx where xxx is the complete IP address of the destination device you wa...

Page 9: ...n It is recommended that whip antennas are not used to simulate a long distance RF link RF attenuators are far superior to antennas for short distance bench testing as the attenuation of the RF signal...

Page 10: ...the radio you will need to reset the radio configuration to factory default This can be done by powering up the radio wait 45 seconds depress the factory default switch using a paper clip or similar t...

Page 11: ...some critical items for point to point operation For each configuration item help text is provided on the HTML programmer interface If you are manually specifying IP addresses ensure you record them f...

Page 12: ...Point Step 8 Embedded Diagnostics Testing 8 1 Review Access Point Start your web browser and insert the IP address of the J Series Access Point as recorded in Step 6 into the URL Once loaded click on...

Page 13: ...cord After an Indicative Packet Error test has been performed a Commissioning Record can be prepared This facility is activated by clicking on the Commissioning Record button It is recommended that th...

Page 14: ...ass I Division 2 wiring in accordance with the electrical codes The enclosure and wiring are subject to investigation by the local Authority Having Jurisdiction at the time of installation 3 Installat...

Page 15: ...ce operations at closer than this distance is not recommended The antenna used for this transmitter must not be co located in conjunction with any other antenna or transmitter MAXIMUM EIRP FCCRegulati...

Page 16: ...ROL MICROSYSTEMS www controlmicrosystems com Ottawa n Calgary n Denver n Houston n Melbourne n Leiden Within North America 888 267 2232 n Outside North America 613 591 1943 Control Microsystems reserv...